Embedded SW Release note - Version 1.4.6.34 - Pack 2+
=============================================================
Validate IFS and cartridge location on manual waste handling - bug #3033
better handling of powerstep01 configuration and motors clocks
waste level: logs, fixed reading during waste filling,
fix PT100 reading in WHS //important, OK
improve diespensers reading in I2C timing //important OK
alarm handling: fix report (mid tank empty)
diagnostics - waste level in liters
Heating and process - avoid activating all heaters at once. tested for flat head.
Heating - remove alarms when colling dwn due to change of RML or idle mode
Thread - improve feeder tension handling
system: hold initalization process after 3 failures to enable code / parameters change and debugging
Diffstat (limited to 'Software/Embedded_SW/Embedded/Modules/AlarmHandling')
| -rw-r--r-- | Software/Embedded_SW/Embedded/Modules/AlarmHandling/AlarmHandling.c | 5 |
1 files changed, 5 insertions, 0 deletions
diff --git a/Software/Embedded_SW/Embedded/Modules/AlarmHandling/AlarmHandling.c b/Software/Embedded_SW/Embedded/Modules/AlarmHandling/AlarmHandling.c index 356f192a3..1c2b6662d 100644 --- a/Software/Embedded_SW/Embedded/Modules/AlarmHandling/AlarmHandling.c +++ b/Software/Embedded_SW/Embedded/Modules/AlarmHandling/AlarmHandling.c @@ -652,6 +652,9 @@ JobEndReasonEnum getEndReason(uint32_t AlarmId) usnprintf(AlarmReasonStr, 100, "Alarm %d type %d caused a job stop",AlarmId,AlarmItem[AlarmId].EventType); return JOB_OTHER_ALARM; } + case ALARM_SOURCE_TYPE__FluidLevelAlarm: + usnprintf(AlarmReasonStr, 100, "Midtank %d is empty",AlarmItem[AlarmId].DeviceId); + return JOB_OUT_OF_DYE; default: usnprintf(AlarmReasonStr, 100, "Alarm %d type %d caused a job stop",AlarmId,AlarmItem[AlarmId].EventType); return JOB_OTHER_ALARM; @@ -993,6 +996,8 @@ JobEndReasonEnum AlarmHandlingPrepareJob(void *CurrentJob) if (FoundReason != JOB_OK) { JobEndReason = getEndReason(AlarmId); + if (JobEndReason!=FoundReason) + ReportWithPackageFilter(AlarmFilter,"end reason mismatch!!!", __FILE__,AlarmId,JobEndReason, RpMessage, FoundReason, 0); //AbortJob(AlarmReasonStr); //PrepareReady(Module_Alarms,ModuleFail); ReportWithPackageFilter(AlarmFilter,AlarmReasonStr, __FILE__,__LINE__,AlarmId, RpMessage, DEBUG_LOG_CATEGORY__Error, 0); |