diff options
| author | Shlomo Hecht <shlomo@twine-s.com> | 2018-10-09 10:33:57 +0300 |
|---|---|---|
| committer | Shlomo Hecht <shlomo@twine-s.com> | 2018-10-09 10:33:57 +0300 |
| commit | 67ca14bb9524cf610cc4c638f132cfca84bacbee (patch) | |
| tree | 9fcc8140ab07822fb01136f8435b8a3904789b53 /Software/Embedded_SW/Embedded/Modules/General/process.c | |
| parent | f46208a0f7ec63f5435842a8023a7d3e4e0730f7 (diff) | |
| download | Tango-67ca14bb9524cf610cc4c638f132cfca84bacbee.tar.gz Tango-67ca14bb9524cf610cc4c638f132cfca84bacbee.zip | |
Heaters PID
Diffstat (limited to 'Software/Embedded_SW/Embedded/Modules/General/process.c')
| -rw-r--r-- | Software/Embedded_SW/Embedded/Modules/General/process.c | 20 |
1 files changed, 10 insertions, 10 deletions
diff --git a/Software/Embedded_SW/Embedded/Modules/General/process.c b/Software/Embedded_SW/Embedded/Modules/General/process.c index ec2d9a9fe..8fc9434cb 100644 --- a/Software/Embedded_SW/Embedded/Modules/General/process.c +++ b/Software/Embedded_SW/Embedded/Modules/General/process.c @@ -148,16 +148,16 @@ void ProcessRequestFunc(MessageContainer* requestContainer) REPORT_MSG (ProcessParams->dryerzone1temp,"Process Params Dryer"); - if (ProcessParams->dryerzone1temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->dryerzone2temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->dryerzone3temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->mixertemp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone1temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone2temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone3temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone4temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone5temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; - if (ProcessParams->headzone6temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__GENERAL_ERROR; + if (ProcessParams->dryerzone1temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->dryerzone2temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->dryerzone3temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->mixertemp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone1temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone2temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone3temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone4temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone5temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; + if (ProcessParams->headzone6temp > MAX_ALLOWED_TEMPERATURE) status = ERROR_CODE__INVALID_PARAMETER; if (status == 0) status = HandleProcessParameters(ProcessParams); |