initial blower value 2/3 of process value. build pressure in cleaner. stop job on waste overlow or cartridge inserted
Diffstat (limited to 'Software/Embedded_SW/Embedded/Modules/IFS')
| -rw-r--r-- | Software/Embedded_SW/Embedded/Modules/IFS/ifs.c | 10 |
1 files changed, 4 insertions, 6 deletions
diff --git a/Software/Embedded_SW/Embedded/Modules/IFS/ifs.c b/Software/Embedded_SW/Embedded/Modules/IFS/ifs.c index bfffb0d9b..1054da894 100644 --- a/Software/Embedded_SW/Embedded/Modules/IFS/ifs.c +++ b/Software/Embedded_SW/Embedded/Modules/IFS/ifs.c @@ -141,11 +141,8 @@ bool CartridgeInkFull() CartridgeFinishedCount = 0; Report("IFS_filling ", __FILE__,__LINE__,int_MidTank_Pressure_1000, RpMessage, int_MidTank_Pressure_1000, 0); /**** detect if the MidTank_Pressure is the same, 5 times ****/ - if (DetectIfCartridgeFinished(int_MidTank_Pressure_1000)) { - //currently sensor work properly only until 1.6 - 1.8 Liter (TBD) - Report("DetectIfCartridgeFinished", __FILE__,__LINE__,int_MidTank_Pressure_1000, RpMessage, int_MidTank_Pressure_1000, 0); - //return true; - } + if (DetectIfCartridgeFinished(int_MidTank_Pressure_1000)) + return true; } return false; } @@ -274,7 +271,8 @@ void midTankStateMachine(void) Report("Power-down in process", __FILE__, __LINE__, 0, RpMessage, 0, 0); break; } - + if (!RdInkCartridgeSensor()) + break; //check RFID? (TBD) // send request for validation to ppc |