diff options
| author | Shlomo Hecht <shlomo@twine-s.com> | 2019-10-16 16:52:25 +0300 |
|---|---|---|
| committer | Shlomo Hecht <shlomo@twine-s.com> | 2019-10-16 16:52:25 +0300 |
| commit | 657bfe0fa9204f593ffe7c0c37f4027a6b7c1af5 (patch) | |
| tree | 3a1b7c8654a7862648db31288795fdc562f0cdb4 /Software/Stubs Collection | |
| parent | d27432fbfa2707bbe77704ad8eab80ccb68673d5 (diff) | |
| download | Tango-657bfe0fa9204f593ffe7c0c37f4027a6b7c1af5.tar.gz Tango-657bfe0fa9204f593ffe7c0c37f4027a6b7c1af5.zip | |
minor fixes
Diffstat (limited to 'Software/Stubs Collection')
| -rw-r--r-- | Software/Stubs Collection/stubs/embeddedparametersbuild.cs | 16 |
1 files changed, 9 insertions, 7 deletions
diff --git a/Software/Stubs Collection/stubs/embeddedparametersbuild.cs b/Software/Stubs Collection/stubs/embeddedparametersbuild.cs index 50af48f35..da7237183 100644 --- a/Software/Stubs Collection/stubs/embeddedparametersbuild.cs +++ b/Software/Stubs Collection/stubs/embeddedparametersbuild.cs @@ -31,8 +31,8 @@ configurationParameters.OverHeatCountLimit = 3; configurationParameters.UnderHeatCountLimit = 3; // time of motor activity before opening the valve or after closing the valve, in milliseconds -configurationParameters.CloseValveTimeout = 50; -configurationParameters.OpenValveTimeout = 50; +configurationParameters.CloseValveTimeout = 10; +configurationParameters.OpenValveTimeout = 10; //backlash after filling - target pressure, timoeout, time staps (speed will be added in general parameters) configurationParameters.InitialDispenserPressure = 1.05; @@ -41,7 +41,7 @@ configurationParameters.InitialDispenserTimeLag = 100; //job prepare - build pressure in dispensers - target pressure, timoeout, time staps, speed configurationParameters.DispenserBuildPressureSpeed = 950; //no more than 1000 -configurationParameters.DispenserBuildPressureLimit = 1.05; +configurationParameters.DispenserBuildPressureLimit = 0.35; configurationParameters.DispenserBuildPressureTimeout = 80000; configurationParameters.DispenserBuildPressureLag = 50; @@ -62,7 +62,7 @@ configurationParameters.DispenserPresegmentWFCF = 40; configurationParameters.IDSPreSegmentWFCFTimeBeforeSegment = 30000; //flag: start heaters according to saved process parameters upon init? -configurationParameters.StartHeatingOnInitSequence = false; +configurationParameters.StartHeatingOnInitSequence = true; // current test for the heaters - alarm thresholds configurationParameters.CurrentAlarmLowLimit = 0.80; @@ -70,9 +70,11 @@ configurationParameters.CurrentAlarmHighLimit = 1.07; configurationParameters.IDSSegmentRefillTimeout = 5000; configurationParameters.IDSPreSegmentBuildupTime = 5000; +//cleaning!!!!!!!!!! configurationParameters.IDSCleaningSpeed = 800; configurationParameters.IDSCleaningStopBeforeSegmentTime = 3000; configurationParameters.IDSCleaningStartSprayPreSegmentTime = 1000; + configurationParameters.IDSLeftCleaningMotorSpeed = 30; configurationParameters.IDSRightCleaningMotorSpeed = 23; configurationParameters.SwitchToIdleTimeinSeconds = 3600; @@ -111,17 +113,17 @@ configurationParameters.GeneralParameters.Add(WinderBackToBaseTime); /*6*/ Double DispenserInitialPressureSpeed = new Double(); -DispenserInitialPressureSpeed = 1000.0; +DispenserInitialPressureSpeed = 800.0; configurationParameters.GeneralParameters.Add(DispenserInitialPressureSpeed); /*7*/ Double SetDiagnosticMode = new Double(); -SetDiagnosticMode =3.0; +SetDiagnosticMode = 1.0; configurationParameters.GeneralParameters.Add(SetDiagnosticMode); /*8*/ Double SetAutoFill = new Double(); -SetAutoFill = 1.0; +SetAutoFill = 3.0; configurationParameters.GeneralParameters.Add(SetAutoFill); File.WriteAllBytes("C:/temp/EmbParam.cfg",configurationParameters.ToBytes()); |
