aboutsummaryrefslogtreecommitdiffstats
path: root/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs
diff options
context:
space:
mode:
authorMirta <mirta@twine-s.com>2020-12-30 16:39:52 +0200
committerMirta <mirta@twine-s.com>2020-12-30 16:39:52 +0200
commit00a491d93733d4625ad329b2ba8237f445364b3f (patch)
tree4b24c6fa78d7648f4bb7cefafa464bb0b063fec4 /Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs
parent124ad4150f80c6846fdee41dbbda9848c105f6e5 (diff)
downloadTango-00a491d9.tar.gz
Tango-00a491d9.zip
merge
Diffstat (limited to 'Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs')
-rw-r--r--Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs85
1 files changed, 24 insertions, 61 deletions
diff --git a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs
index 47fe19a05..40dc82d29 100644
--- a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs
+++ b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.HardwareDesigner/ViewModels/MainViewVM.cs
@@ -16,9 +16,6 @@ using Tango.Core.ExtensionMethods;
using Tango.MachineStudio.HardwareDesigner.Views;
using Microsoft.Win32;
using System.IO;
-using Tango.BL.ActionLogs;
-using Tango.MachineStudio.Common.Authentication;
-using Tango.BL.DTO;
namespace Tango.MachineStudio.HardwareDesigner.ViewModels
{
@@ -27,9 +24,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
private INotificationProvider _notification;
private bool _isNew;
private ObservablesContext _db;
- private IActionLogManager _actionLogManager;
- private IAuthenticationProvider _authentication;
- private HardwareVersionDTO _hwBeforeSave;
private HardwareVersion _selectedVersion;
public HardwareVersion SelectedVersion
@@ -51,8 +45,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
get { return _selectedHardwareObject; }
set
{
- _selectedHardwareObject = null;
- RaisePropertyChangedAuto();
_selectedHardwareObject = value;
RaisePropertyChangedAuto();
RaisePropertyChanged(nameof(SelectedHardwareObjectTypeName));
@@ -121,11 +113,9 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
public RelayCommand ImportHardwareVersionCommand { get; set; }
- public MainViewVM(INotificationProvider notification, IActionLogManager actionLogManager, IAuthenticationProvider authentication)
+ public MainViewVM(INotificationProvider notification)
{
_notification = notification;
- _actionLogManager = actionLogManager;
- _authentication = authentication;
CurrentVersion = new HardwareVersion();
@@ -193,8 +183,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
_db.HardwareVersions.Add(hv);
await _db.SaveChangesAsync();
- _actionLogManager.InsertLog(BL.Enumerations.ActionLogType.HardwareVersionImported, _authentication.CurrentUser, CurrentVersion.Name, CurrentVersion, "New hardware version imported using Machine Studio.");
-
RefreshVersions();
InvokeUI(() =>
@@ -233,7 +221,7 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
private void CopyParameters(object obj)
{
- obj.MapPropertiesTo(SelectedHardwareObject, MappingFlags.ValueTypesOnly,
+ obj.MapPrimitivesTo(SelectedHardwareObject,
(prop) =>
!prop.PropertyType.IsEnum
&&
@@ -248,20 +236,20 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
_db = ObservablesContext.CreateDefault();
- CurrentVersion.HardwareMotors = _db.HardwareMotorTypes.ToList().Select(x => new HardwareMotor() { HardwareMotorType = x }).OrderByAlphaNumeric(x => x.HardwareMotorType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwareDancers = _db.HardwareDancerTypes.ToList().Select(x => new HardwareDancer() { HardwareDancerType = x }).OrderByAlphaNumeric(x => x.HardwareDancerType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwarePidControls = _db.HardwarePidControlTypes.ToList().Select(x => new HardwarePidControl() { HardwarePidControlType = x }).OrderByAlphaNumeric(x => x.HardwarePidControlType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwareWinders = _db.HardwareWinderTypes.ToList().Select(x => new HardwareWinder() { HardwareWinderType = x }).OrderByAlphaNumeric(x => x.HardwareWinderType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwareSpeedSensors = _db.HardwareSpeedSensorTypes.ToList().Select(x => new HardwareSpeedSensor() { HardwareSpeedSensorType = x }).OrderByAlphaNumeric(x => x.HardwareSpeedSensorType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwareBlowers = _db.HardwareBlowerTypes.ToList().Select(x => new HardwareBlower() { HardwareBlowerType = x }).OrderByAlphaNumeric(x => x.HardwareBlowerType.Description).ToSynchronizedObservableCollection();
- CurrentVersion.HardwareBreakSensors = _db.HardwareBreakSensorTypes.ToList().Select(x => new HardwareBreakSensor() { HardwareBreakSensorType = x }).OrderByAlphaNumeric(x => x.HardwareBreakSensorType.Description).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareMotors = _db.HardwareMotorTypes.ToList().Select(x => new HardwareMotor() { HardwareMotorType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareDancers = _db.HardwareDancerTypes.ToList().Select(x => new HardwareDancer() { HardwareDancerType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwarePidControls = _db.HardwarePidControlTypes.ToList().Select(x => new HardwarePidControl() { HardwarePidControlType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareWinders = _db.HardwareWinderTypes.ToList().Select(x => new HardwareWinder() { HardwareWinderType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareSpeedSensors = _db.HardwareSpeedSensorTypes.ToList().Select(x => new HardwareSpeedSensor() { HardwareSpeedSensorType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareBlowers = _db.HardwareBlowerTypes.ToList().Select(x => new HardwareBlower() { HardwareBlowerType = x }).ToSynchronizedObservableCollection();
+ CurrentVersion.HardwareBreakSensors = _db.HardwareBreakSensorTypes.ToList().Select(x => new HardwareBreakSensor() { HardwareBreakSensorType = x }).ToSynchronizedObservableCollection();
}
private void RefreshVersions()
{
using (var db = ObservablesContext.CreateDefault())
{
- _hardwareVersions = db.HardwareVersions.OrderByDescending(x => x.Version).ToObservableCollection();
+ _hardwareVersions = db.HardwareVersions.ToObservableCollection();
InvokeUI(() =>
{
RaisePropertyChanged(nameof(HardwareVersions));
@@ -349,8 +337,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
});
CurrentVersion.HardwareBreakSensors = CurrentVersion.HardwareBreakSensors.OrderBy(x => x.HardwareBreakSensorType.Code).ToSynchronizedObservableCollection();
-
- _hwBeforeSave = HardwareVersionDTO.FromObservable(CurrentVersion);
});
}
@@ -360,34 +346,24 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
{
using (_notification.PushTaskItem("Loading hardware version..."))
{
- try
+ IsFree = false;
+
+ await Task.Factory.StartNew(() =>
{
- IsFree = false;
+ _isNew = false;
+ var selectedVersion = SelectedVersion;
+ RefreshVersions();
+ var version = _hardwareVersions.SingleOrDefault(X => X.Guid == selectedVersion.Guid);
+ CreateVersionView(SelectedVersion);
- await Task.Factory.StartNew(() =>
+ InvokeUI(() =>
{
- _isNew = false;
- var selectedVersion = SelectedVersion;
- RefreshVersions();
- var version = _hardwareVersions.SingleOrDefault(X => X.Guid == selectedVersion.Guid);
- CreateVersionView(SelectedVersion);
-
- InvokeUI(() =>
- {
- _selectedVersion = version;
- RaisePropertyChanged(nameof(SelectedVersion));
- });
+ _selectedVersion = version;
+ RaisePropertyChanged(nameof(SelectedVersion));
});
- }
- catch (Exception ex)
- {
- LogManager.Log(ex, "Error loading hardware version.");
- _notification.ShowError($"Error loading the selected hardware version.\n{ex.FlattenMessage()}");
- }
- finally
- {
- IsFree = true;
- }
+ });
+
+ IsFree = true;
}
}
@@ -415,8 +391,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
_db.HardwareVersions.Add(CurrentVersion);
_db.SaveChanges();
- _actionLogManager.InsertLog(BL.Enumerations.ActionLogType.HardwareVersionCreated, _authentication.CurrentUser, CurrentVersion.Name, CurrentVersion, "New hardware version created using Machine Studio.");
-
RefreshVersions();
InvokeUI(() =>
@@ -444,13 +418,7 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
await Task.Factory.StartNew(() =>
{
- CurrentVersion.LastUpdated = DateTime.UtcNow;
_db.SaveChanges();
-
- var dtoAfter = HardwareVersionDTO.FromObservable(CurrentVersion);
- _actionLogManager.InsertLog(BL.Enumerations.ActionLogType.HardwareVersionSaved, _authentication.CurrentUser, _hwBeforeSave.Name, _hwBeforeSave, dtoAfter, "Hardware Version saved using Machine Studio.");
- _hwBeforeSave = dtoAfter;
-
RefreshVersions();
InvokeUI(() =>
@@ -492,9 +460,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
cloned.Version = HardwareVersions.Max(x => x.Version) + 1;
_db.HardwareVersions.Add(cloned);
_db.SaveChanges();
-
- _actionLogManager.InsertLog(BL.Enumerations.ActionLogType.HardwareVersionCreated, _authentication.CurrentUser, cloned.Name, cloned, "New hardware version cloned using Machine Studio.");
-
RefreshVersions();
InvokeUI(() =>
@@ -530,8 +495,6 @@ namespace Tango.MachineStudio.HardwareDesigner.ViewModels
await CurrentVersion.DeleteCascadeAsync(_db);
- _actionLogManager.InsertLog(BL.Enumerations.ActionLogType.HardwareVersionDeleted, _authentication.CurrentUser, CurrentVersion.Name, _hwBeforeSave, "Hardware version deleted using Machine Studio.", true);
-
await Task.Factory.StartNew(() =>
{
SelectedVersion = null;