diff options
| author | Avi Levkovich <avi@twine-s.com> | 2018-08-06 16:12:38 +0300 |
|---|---|---|
| committer | Avi Levkovich <avi@twine-s.com> | 2018-08-06 16:12:38 +0300 |
| commit | 778408ff6140099aace10a915bc0296d71f967fe (patch) | |
| tree | 40bbfabe96128d777f793f0b8d14b059d0f88ce2 /Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs | |
| parent | 65d06cf7d023cfed8a1619cb2f81279b1d5096f8 (diff) | |
| parent | ce34a07e9ae75c9172425322248dc2fd1754852e (diff) | |
| download | Tango-778408ff6140099aace10a915bc0296d71f967fe.tar.gz Tango-778408ff6140099aace10a915bc0296d71f967fe.zip | |
Merge branch 'master' of https://twinetfs.visualstudio.com/_git/Tango
Diffstat (limited to 'Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs')
| -rw-r--r-- | Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs | 78 |
1 files changed, 78 insertions, 0 deletions
diff --git a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs index cd7582fe9..f79ebb29b 100644 --- a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs +++ b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.Technician/ViewModels/MachineTechViewVM.cs @@ -617,6 +617,14 @@ namespace Tango.MachineStudio.Technician.ViewModels { CreateElement<SpeedSensorElementEditor, SpeedSensorItem, HardwareSpeedSensorType>(bounds, Adapter.HardwareSpeedSensorTypes.FirstOrDefault()); } + else if (item is BlowerItem) + { + CreateElement<BlowerElementEditor, BlowerItem, HardwareBlowerType>(bounds, Adapter.HardwareBlowerTypes.FirstOrDefault()); + } + else if (item is BreakSensorItem) + { + CreateElement<BreakSensorElementEditor, BreakSensorItem, HardwareBreakSensorType>(bounds, Adapter.HardwareBreakSensorTypes.FirstOrDefault()); + } else if (item is ProcessParametersItem) { var editor = CreateElement<ProcessParametersElementEditor, ProcessParametersItem, object>(bounds, null); @@ -746,6 +754,16 @@ namespace Tango.MachineStudio.Technician.ViewModels (item as SpeedSensorItem).HardwareSpeedSensorType = Adapter.HardwareSpeedSensorTypes.FirstOrDefault(x => x.Guid == item.ItemGuid); CreateElement<SpeedSensorElementEditor>(item); } + else if (item is BlowerItem) + { + (item as BlowerItem).HardwareBlowerType = Adapter.HardwareBlowerTypes.FirstOrDefault(x => x.Guid == item.ItemGuid); + CreateElement<BlowerElementEditor>(item); + } + else if (item is BreakSensorItem) + { + (item as BreakSensorItem).HardwareBreakSensorType = Adapter.HardwareBreakSensorTypes.FirstOrDefault(x => x.Guid == item.ItemGuid); + CreateElement<BreakSensorElementEditor>(item); + } else if (item is ProcessParametersItem) { var editor = CreateElement<ProcessParametersElementEditor>(item); @@ -1610,6 +1628,26 @@ namespace Tango.MachineStudio.Technician.ViewModels } } + foreach (var blowerConfig in config.Blowers) + { + var itemConfig = BlowerItem.BlowerConfigurations.SingleOrDefault(x => x.HardwareBlowerType.Code == blowerConfig.HardwareBlowerType.ToInt32()); + + if (itemConfig != null) + { + blowerConfig.MapPrimitivesTo(itemConfig); + } + } + + foreach (var breakSensorConfig in config.BreakSensors) + { + var itemConfig = BreakSensorItem.BreakSensorConfigurations.SingleOrDefault(x => x.HardwareBreakSensorType.Code == breakSensorConfig.HardwareBreakSensorType.ToInt32()); + + if (itemConfig != null) + { + breakSensorConfig.MapPrimitivesTo(itemConfig); + } + } + _notification.ShowInfo("Visual elements synced to the last uploaded hardware configuration."); } else @@ -1674,6 +1712,26 @@ namespace Tango.MachineStudio.Technician.ViewModels } } + foreach (var blowerConfig in hw.HardwareBlowers) + { + var itemConfig = BlowerItem.BlowerConfigurations.SingleOrDefault(x => x.HardwareBlowerType.Code == blowerConfig.HardwareBlowerType.Code); + + if (itemConfig != null) + { + itemConfig.MapPrimitivesTo(blowerConfig); + } + } + + foreach (var breakSensorConfig in hw.HardwareBreakSensors) + { + var itemConfig = BreakSensorItem.BreakSensorConfigurations.SingleOrDefault(x => x.HardwareBreakSensorType.Code == breakSensorConfig.HardwareBreakSensorType.Code); + + if (itemConfig != null) + { + itemConfig.MapPrimitivesTo(breakSensorConfig); + } + } + using (_notification.PushTaskItem("Uploading hardware configuration...")) { try @@ -1745,6 +1803,26 @@ namespace Tango.MachineStudio.Technician.ViewModels } } + foreach (var blowerSensorConfig in hw.HardwareBlowers) + { + var itemConfig = BlowerItem.BlowerConfigurations.SingleOrDefault(x => x.HardwareBlowerType.Code == blowerSensorConfig.HardwareBlowerType.Code); + + if (itemConfig != null) + { + blowerSensorConfig.MapPrimitivesTo(itemConfig); + } + } + + foreach (var breakSensorConfig in hw.HardwareBreakSensors) + { + var itemConfig = BreakSensorItem.BreakSensorConfigurations.SingleOrDefault(x => x.HardwareBreakSensorType.Code == breakSensorConfig.HardwareBreakSensorType.Code); + + if (itemConfig != null) + { + breakSensorConfig.MapPrimitivesTo(itemConfig); + } + } + if (showMessage) { _notification.ShowInfo("Visual elements synced to hardware version " + hw.Name + ", " + hw.Version + "."); |
