diff options
| author | Roy <Roy.mail.net@gmail.com> | 2023-09-05 10:12:43 +0300 |
|---|---|---|
| committer | Roy <Roy.mail.net@gmail.com> | 2023-09-05 10:12:43 +0300 |
| commit | dbb1af0b580ff8880159ffe9f1f430888f3a6819 (patch) | |
| tree | 57a6af69cd3630cddb187a1895305f0bfec4de0b /Software/Visual_Studio/Tango.BL | |
| parent | 1c116952716422cce38b4e36dd3193d0700debdb (diff) | |
| download | Tango-dbb1af0b580ff8880159ffe9f1f430888f3a6819.tar.gz Tango-dbb1af0b580ff8880159ffe9f1f430888f3a6819.zip | |
Updated events definitions.
Diffstat (limited to 'Software/Visual_Studio/Tango.BL')
| -rw-r--r-- | Software/Visual_Studio/Tango.BL/Enumerations/EventTypes.cs | 204 |
1 files changed, 177 insertions, 27 deletions
diff --git a/Software/Visual_Studio/Tango.BL/Enumerations/EventTypes.cs b/Software/Visual_Studio/Tango.BL/Enumerations/EventTypes.cs index 93732c9f3..27a2b78e3 100644 --- a/Software/Visual_Studio/Tango.BL/Enumerations/EventTypes.cs +++ b/Software/Visual_Studio/Tango.BL/Enumerations/EventTypes.cs @@ -698,10 +698,10 @@ namespace Tango.BL.Enumerations DRYER_HEATERS_ZONE_2_CURRENT_LOOP_BREAK = 4014, /// <summary> - /// (Dryer fan RPM is too low. Cannot execute job) + /// (Dryer filter is clogged. Cannot execute job) /// </summary> - [Description("Dryer fan RPM is too low. Cannot execute job")] - DRYER_FAN_RPM_TOO_LOW = 4015, + [Description("Dryer filter is clogged. Cannot execute job")] + DRYER_FILTER_IS_CLOGGED = 4015, /// <summary> /// (Dryer fan stopped. Cannot execute job) @@ -2654,16 +2654,16 @@ namespace Tango.BL.Enumerations E_DRYER_DOOR_OPEN = 103002, /// <summary> - /// (Dryer thermal cutoff activated. Cannot execute job) + /// (Dryer temperatue too high. Cannot execute job) /// </summary> - [Description("Dryer thermal cutoff activated. Cannot execute job")] - E_DRYER_THERMAL_CUTOFF = 103003, + [Description("Dryer temperatue too high. Cannot execute job")] + E_DRYER_HEATER_1_TEMPERATURE_TOO_HIGH = 103003, /// <summary> - /// (Tunnel thermal cutoff activated. Cannot execute job) + /// (Tunnel temperature too high. Cannot execute job) /// </summary> - [Description("Tunnel thermal cutoff activated. Cannot execute job")] - E_TUNNEL_THERMAL_CUTOFF = 103004, + [Description("Tunnel temperature too high. Cannot execute job")] + E_TUNNEL_HEATER_TEMPERATURE_TOO_HIGH = 103004, /// <summary> /// (Dyeing head thermal cutoff activated. Cannot execute job) @@ -2684,16 +2684,16 @@ namespace Tango.BL.Enumerations E_LUBRICATION_THERMAL_CUTOFF = 103007, /// <summary> - /// (No air flow in tunnel. Cannot execute job) + /// (No suction in tunnel. Cannot execute job) /// </summary> - [Description("No air flow in tunnel. Cannot execute job")] + [Description("No suction in tunnel. Cannot execute job")] E_TUNNEL_AIR_FLOW_SWITCH = 103008, /// <summary> - /// (No Suction from recycled ink handling system. Cannot execute job) + /// (No Suction in dryer. Cannot execute job) /// </summary> - [Description("No Suction from recycled ink handling system. Cannot execute job")] - E_WHS_AIR_FLOW_SWITCH = 103009, + [Description("No Suction in dryer. Cannot execute job")] + E_DRYER_AIR_FLOW_SWITCH = 103009, /// <summary> /// (Air filter not present. Cannot execute job) @@ -2702,6 +2702,18 @@ namespace Tango.BL.Enumerations E_AIR_FILTER_NOT_PRESENT = 103010, /// <summary> + /// (Dryer temperature too high. Cannot execute job) + /// </summary> + [Description("Dryer temperature too high. Cannot execute job")] + E_DRYER_HEATER_2_TEMPERATURE_TOO_HIGH = 103011, + + /// <summary> + /// (Dryer temperature too high. Cannot execute job) + /// </summary> + [Description("Dryer temperature too high. Cannot execute job")] + E_DRYER_HEATER_3_TEMPERATURE_TOO_HIGH = 103012, + + /// <summary> /// (Software error has occurred. Cannot execute job ) /// </summary> [Description("Software error has occurred. Cannot execute job ")] @@ -2822,6 +2834,30 @@ namespace Tango.BL.Enumerations E_NO_COMMUNICATION_WITH_MAIN_BOARD = 105017, /// <summary> + /// (Communication error. Cannot execute job) + /// </summary> + [Description("Communication error. Cannot execute job")] + E_NO_COMMUNICATION_WITH_BTSR_5 = 105018, + + /// <summary> + /// (Communication error. Cannot execute job) + /// </summary> + [Description("Communication error. Cannot execute job")] + E_NO_COMMUNICATION_WITH_BTSR_6 = 105019, + + /// <summary> + /// (Communication error. Cannot execute job) + /// </summary> + [Description("Communication error. Cannot execute job")] + E_NO_COMMUNICATION_WITH_BTSR_7 = 105020, + + /// <summary> + /// (Communication error. Cannot execute job) + /// </summary> + [Description("Communication error. Cannot execute job")] + E_NO_COMMUNICATION_WITH_BTSR_8 = 105021, + + /// <summary> /// (Door is open. Cannot execute job) /// </summary> [Description("Door is open. Cannot execute job")] @@ -2948,64 +2984,118 @@ namespace Tango.BL.Enumerations E_THREAD_MISSING = 107015, /// <summary> + /// (Loading comb not in place. Cannot execute job) + /// </summary> + [Description("Loading comb not in place. Cannot execute job")] + E_LOADING_COMB_NOT_IN_PLACE = 107016, + + /// <summary> + /// (BTSR malfunction. Cannot execute job) + /// </summary> + [Description("BTSR malfunction. Cannot execute job")] + E_BTSR_5_MALFUNCTION = 107017, + + /// <summary> + /// (BTSR malfunction. Cannot execute job) + /// </summary> + [Description("BTSR malfunction. Cannot execute job")] + E_BTSR_6_MALFUNCTION = 107018, + + /// <summary> + /// (BTSR malfunction. Cannot execute job) + /// </summary> + [Description("BTSR malfunction. Cannot execute job")] + E_BTSR_7_MALFUNCTION = 107019, + + /// <summary> + /// (BTSR malfunction. Cannot execute job) + /// </summary> + [Description("BTSR malfunction. Cannot execute job")] + E_BTSR_8_MALFUNCTION = 107020, + + /// <summary> + /// (Tension is out of range. Cannot execute job) + /// </summary> + [Description("Tension is out of range. Cannot execute job")] + E_TENSION_IN_BTSR_5_IS_OUT_OF_RANGE = 107021, + + /// <summary> + /// (Tension is out of range. Cannot execute job) + /// </summary> + [Description("Tension is out of range. Cannot execute job")] + E_TENSION_IN_BTSR_6_IS_OUT_OF_RANGE = 107022, + + /// <summary> + /// (Tension is out of range. Cannot execute job) + /// </summary> + [Description("Tension is out of range. Cannot execute job")] + E_TENSION_IN_BTSR_7_IS_OUT_OF_RANGE = 107023, + + /// <summary> + /// (Tension is out of range. Cannot execute job) + /// </summary> + [Description("Tension is out of range. Cannot execute job")] + E_TENSION_IN_BTSR_8_IS_OUT_OF_RANGE = 107024, + + /// <summary> /// (Temperature in dyeing head is too high. Cannot execute job) /// </summary> [Description("Temperature in dyeing head is too high. Cannot execute job")] - E_DYEING_HEAD_ZONE_1_OVERTEMPERATURE = 108000, + E_DYEING_HEAD_ZONE_1_OVERTEMPERATURE_A = 108000, /// <summary> /// (Temperature in dyeing head is too high. Cannot execute job) /// </summary> [Description("Temperature in dyeing head is too high. Cannot execute job")] - E_DYEING_HEAD_ZONE_2_OVERTEMPERATURE = 108001, + E_DYEING_HEAD_ZONE_2_OVERTEMPERATURE_A = 108001, /// <summary> /// (Temperature in dyeing head is too high. Cannot execute job) /// </summary> [Description("Temperature in dyeing head is too high. Cannot execute job")] - E_DYEING_HEAD_ZONE_3_OVERTEMPERATURE = 108002, + E_DYEING_HEAD_ZONE_3_OVERTEMPERATURE_A = 108002, /// <summary> /// (Temperature in mixer is too high. Cannot execute job) /// </summary> [Description("Temperature in mixer is too high. Cannot execute job")] - E_MIXER_1_OVERTEMPERATURE = 108003, + E_MIXER_1_OVERTEMPERATURE_A = 108003, /// <summary> /// (Temperature in mixer is too high. Cannot execute job) /// </summary> [Description("Temperature in mixer is too high. Cannot execute job")] - E_MIXER_2_OVERTEMPERATURE = 108004, + E_MIXER_2_OVERTEMPERATURE_A = 108004, /// <summary> /// (Temperature in tunnel is too high. Cannot execute job) /// </summary> [Description("Temperature in tunnel is too high. Cannot execute job")] - E_TUNNEL_OVERTEMPERATURE = 108005, + E_TUNNEL_OVERTEMPERATURE_A = 108005, /// <summary> /// (Temperature in dryer is too high. Cannot execute job) /// </summary> [Description("Temperature in dryer is too high. Cannot execute job")] - E_DRYER_HEATER_1_OVERTEMPERATURE = 108007, + E_DRYER_HEATER_1_OVERTEMPERATURE_A = 108007, /// <summary> /// (Temperature in dryer is too high. Cannot execute job) /// </summary> [Description("Temperature in dryer is too high. Cannot execute job")] - E_DRYER_HEATER_2_OVERTEMPERATURE = 108008, + E_DRYER_HEATER_2_OVERTEMPERATURE_A = 108008, /// <summary> /// (Temperature in dryer is too high. Cannot execute job) /// </summary> [Description("Temperature in dryer is too high. Cannot execute job")] - E_DRYER_HEATER_3_OVERTEMPERATURE = 108009, + E_DRYER_HEATER_3_OVERTEMPERATURE_A = 108009, /// <summary> /// (Temperature in lubricant is too high. Cannot execute job) /// </summary> [Description("Temperature in lubricant is too high. Cannot execute job")] - E_LUBRICANT_OVERTEMPERATURE = 108010, + E_LUBRICANT_OVERTEMPERATURE_A = 108010, /// <summary> /// (Dyeing head is heating up. Cannot execute job) @@ -3071,7 +3161,7 @@ namespace Tango.BL.Enumerations /// (Temperature in dyeing head is too low. Cannot execute job) /// </summary> [Description("Temperature in dyeing head is too low. Cannot execute job")] - E_DYEING_HEAD_ZONE_1_UNDRTEMPERATURE_B = 108021, + E_DYEING_HEAD_ZONE_1_UNDERTEMPERATURE_B = 108021, /// <summary> /// (Temperature in dyeing head is too low. Cannot execute job) @@ -3164,6 +3254,66 @@ namespace Tango.BL.Enumerations E_DRYER_INTERNAL_TEMPERATURE_TOO_LOW = 108036, /// <summary> + /// (Temperature in dyeing head is stabilizing . Cannot execute job) + /// </summary> + [Description("Temperature in dyeing head is stabilizing . Cannot execute job")] + E_DYEING_HEAD_ZONE_1_OVERTEMPERATURE_B = 108037, + + /// <summary> + /// (Temperature in dyeing head is stabilizing . Cannot execute job) + /// </summary> + [Description("Temperature in dyeing head is stabilizing . Cannot execute job")] + E_DYEING_HEAD_ZONE_2_OVERTEMPERATURE_B = 108038, + + /// <summary> + /// (Temperature in dyeing head is stabilizing . Cannot execute job) + /// </summary> + [Description("Temperature in dyeing head is stabilizing . Cannot execute job")] + E_DYEING_HEAD_ZONE_3_OVERTEMPERATURE_B = 108039, + + /// <summary> + /// (Temperature in mixer is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in mixer is stabilizing. Cannot execute job")] + E_MIXER_1_OVERTEMPERATURE_B = 108040, + + /// <summary> + /// (Temperature in mixer is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in mixer is stabilizing. Cannot execute job")] + E_MIXER_2_OVERTEMPERATURE_B = 108041, + + /// <summary> + /// (Temperature in tunnel is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in tunnel is stabilizing. Cannot execute job")] + E_TUNNEL_OVERTEMPERATURE_B = 108042, + + /// <summary> + /// (Temperature in dryer is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in dryer is stabilizing. Cannot execute job")] + E_DRYER_HEATER_1_OVERTEMPERATURE_B = 108043, + + /// <summary> + /// (Temperature in dryer is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in dryer is stabilizing. Cannot execute job")] + E_DRYER_HEATER_2_OVERTEMPERATURE_B = 108044, + + /// <summary> + /// (Temperature in dryer is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in dryer is stabilizing. Cannot execute job")] + E_DRYER_HEATER_3_OVERTEMPERATURE_B = 108045, + + /// <summary> + /// (Temperature in lubricant is stabilizing. Cannot execute job) + /// </summary> + [Description("Temperature in lubricant is stabilizing. Cannot execute job")] + E_LUBRICANT_OVERTEMPERATURE_B = 108046, + + /// <summary> /// (Dyeing head zone current is out of range. Cannot execute job) /// </summary> [Description("Dyeing head zone current is out of range. Cannot execute job")] @@ -3380,9 +3530,9 @@ namespace Tango.BL.Enumerations E_AIR_FILTER_CLOGGED = 111004, /// <summary> - /// (No circulation flow in blower. Cannot execute job) + /// (No circulation flow in dryer. Cannot execute job) /// </summary> - [Description("No circulation flow in blower. Cannot execute job")] + [Description("No circulation flow in dryer. Cannot execute job")] E_NO_CIRCULATION_FLOW_IN_DRYER = 111005, /// <summary> |
