aboutsummaryrefslogtreecommitdiffstats
path: root/Software/PMR
diff options
context:
space:
mode:
Diffstat (limited to 'Software/PMR')
-rw-r--r--Software/PMR/Messages/Diagnostics/EventType.proto89
1 files changed, 67 insertions, 22 deletions
diff --git a/Software/PMR/Messages/Diagnostics/EventType.proto b/Software/PMR/Messages/Diagnostics/EventType.proto
index 33f062b1f..e4135f5de 100644
--- a/Software/PMR/Messages/Diagnostics/EventType.proto
+++ b/Software/PMR/Messages/Diagnostics/EventType.proto
@@ -1336,11 +1336,11 @@ enum EventType
//The dryer door is open. Cannot execute job (Group = Safety, Category = Critical)
E_DRYER_DOOR_OPEN = 103002;
- //Dryer temperatue too high. Cannot execute job (Group = Safety, Category = Critical)
- E_DRYER_HEATER_1_TEMPERATURE_TOO_HIGH = 103003;
+ //Dryer thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical)
+ E_DRYER_THERMAL_CUTOFF = 103003;
- //Tunnel temperature too high. Cannot execute job (Group = Safety, Category = Critical)
- E_TUNNEL_HEATER_TEMPERATURE_TOO_HIGH = 103004;
+ //Tunnel thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical)
+ E_TUNNEL_THERMAL_CUTOFF = 103004;
//Dyeing head thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical)
E_DYEING_HEAD_THERMAL_CUTOFF = 103005;
@@ -1357,14 +1357,17 @@ enum EventType
//No Suction in dryer. Cannot execute job (Group = Safety, Category = Critical)
E_DRYER_AIR_FLOW_SWITCH = 103009;
- //Air filter not present. Cannot execute job (Group = Safety, Category = Critical)
- E_AIR_FILTER_NOT_PRESENT = 103010;
+ //No circulation in dryer. Cannot execute job (Group = Safety, Category = Critical)
+ E_CIRCULATION_AIR_FLOW_SWITCH = 103010;
- //Dryer temperature too high. Cannot execute job (Group = Safety, Category = Critical)
- E_DRYER_HEATER_2_TEMPERATURE_TOO_HIGH = 103011;
+ //Dryer and tunnel thermal cutoffs activated. Cannot execute job (Group = Safety, Category = Critical)
+ E_DRYER_AND_TUNNEL_THERMAL_CUTOFF = 103011;
- //Dryer temperature too high. Cannot execute job (Group = Safety, Category = Critical)
- E_DRYER_HEATER_3_TEMPERATURE_TOO_HIGH = 103012;
+ //Dryer or tunnel thermal cutoff event happened. Cannot execute job (Group = Safety, Category = Critical)
+ E_TCO_EVENT_HAPPENED = 103012;
+
+ //Air flow switch event happened (Group = Safety, Category = Warning)
+ E_AIR_FLOW_SWITCH_EVENT_HAPPENED = 103013;
//Software error has occurred. Cannot execute job (Group = GeneralHardware, Category = Error)
E_UNINTENDED_RESET = 104000;
@@ -1669,6 +1672,12 @@ enum EventType
//Temperature in lubricant is stabilizing. Cannot execute job (Group = Mixer, Category = Warning)
E_LUBRICANT_OVERTEMPERATURE_B = 108046;
+ //IDS ambient temperature is too high. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_IDS_AMBIENT_1_OVERTEMPERATURE = 108047;
+
+ //IDS ambient temperature is too high. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_IDS_AMBIENT_2_OVERTEMPERATURE = 108048;
+
//Dyeing head zone current is out of range. Cannot execute job (Group = DyeingHead, Category = Warning)
E_DYEING_HEAD_ZONE_1_CURRENT_OUT_OF_RANGE = 109000;
@@ -1762,23 +1771,32 @@ enum EventType
//Dyeing head cleaner motor malfuncion. Cannot execute job (Group = DyeingHead, Category = Warning)
E_DYEING_HEAD_CLEANER_MOTOR_MALFUNCTION = 110010;
- //No suction. Cannot execute job. (Group = WasteHandlingSystem, Category = Error)
- E_NO_SUCTION = 111000;
+ //Dryer push blower flow unstable. Cannot execute job. (Group = Dryer, Category = Error)
+ E_DRYER_PUSH_BLOWER_FLOW_UNSTABLE = 111000;
+
+ //Dryer suction blower flow unstable. Cannot execute job (Group = Dryer, Category = Error)
+ E_DRYER_SUCTION_BLOWER_FLOW_UNSTABLE = 111001;
+
+ //Tunnel push blower flow unstable. Cannot execute job (Group = DyeingHead, Category = Error)
+ E_TUNNEL_PUSH_BLOWER_FLOW_UNSTABLE = 111002;
+
+ //Tunnel suction blower flow unstable. Cannot execute job (Group = DyeingHead, Category = Error)
+ E_TUNNEL_SUCTION_BLOWER_FLOW_UNSTABLE = 111003;
- //Dryer blower flow is too low. Cannot execute job (Group = Dryer, Category = Warning)
- E_DRYER_BLOWER_FLOW_TOO_LOW = 111001;
+ //IDS air conditioner malfunction. Cannot execute job (Group = InkDeliverySystem, Category = Warning)
+ E_IDS_AIR_CONDITIONER_MALFUNCTION = 111004;
- //Tunnel blower flow is too low. Cannot execute job (Group = DyeingHead, Category = Warning)
- E_TUNNEL_BLOWER_FLOW_TOO_LOW = 111002;
+ //Dryer push flow too low. Cannot execute job (Group = Dryer, Category = Error)
+ E_DRYER_PUSH_FLOW_TOO_LOW = 111005;
- //Insufficient suction fron WHS. Cannot execute job (Group = WasteHandlingSystem, Category = Error)
- E_INSUFFICIENT_WHS_SUCTION = 111003;
+ //Dryer suction flow too low. Cannot execute job (Group = Dryer, Category = Error)
+ E_DRYER_SUCTION_FLOW_TOO_LOW = 111006;
- //Air filter is clogged. Cannot execute job (Group = WasteHandlingSystem, Category = Error)
- E_AIR_FILTER_CLOGGED = 111004;
+ //Tunnel push flow too low. Cannot execute job (Group = DyeingHead, Category = Error)
+ E_TUNNEL_PUSH_FLOW_TOO_LOW = 111007;
- //No circulation flow in dryer. Cannot execute job (Group = Dryer, Category = Error)
- E_NO_CIRCULATION_FLOW_IN_DRYER = 111005;
+ //Tunnel suction flow too low. Cannot execute job (Group = DyeingHead, Category = Error)
+ E_TUNNEL_SUCTION_FLOW_TOO_LOW = 111008;
//Pressure in @ ink line too high. Cannot execute job (Group = InkDeliverySystem, Category = Error)
E_INK_LINE_1_PRESSURE_TOO_HIGH = 112000;
@@ -1975,4 +1993,31 @@ enum EventType
//Malfunction in @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error)
E_INK_LINE_10_MID_TANK_MALFUNCTION = 112064;
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_16_MALFUNCTION = 112065;
+
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_17_MALFUNCTION = 112066;
+
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_18_MALFUNCTION = 112067;
+
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_19_MALFUNCTION = 112068;
+
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_20_MALFUNCTION = 112069;
+
+ //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error)
+ E_INK_PUMP_21_MALFUNCTION = 112070;
+
+ //The @ tank level is low (Group = InkFillingSystem, Category = Warning)
+ E_INK_LINE_11_MID_TANK_LOW_LEVEL = 112071;
+
+ //Failed to fill @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error)
+ E_INK_LINE_11_MID_TANK_FILL_TIMEOUT = 112072;
+
+ //Malfunction in @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error)
+ E_INK_LINE_11_MID_TANK_MALFUNCTION = 112073;
+
}