diff options
Diffstat (limited to 'Software/PMR')
| -rw-r--r-- | Software/PMR/Messages/Diagnostics/EventType.proto | 89 |
1 files changed, 67 insertions, 22 deletions
diff --git a/Software/PMR/Messages/Diagnostics/EventType.proto b/Software/PMR/Messages/Diagnostics/EventType.proto index 33f062b1f..e4135f5de 100644 --- a/Software/PMR/Messages/Diagnostics/EventType.proto +++ b/Software/PMR/Messages/Diagnostics/EventType.proto @@ -1336,11 +1336,11 @@ enum EventType //The dryer door is open. Cannot execute job (Group = Safety, Category = Critical) E_DRYER_DOOR_OPEN = 103002; - //Dryer temperatue too high. Cannot execute job (Group = Safety, Category = Critical) - E_DRYER_HEATER_1_TEMPERATURE_TOO_HIGH = 103003; + //Dryer thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical) + E_DRYER_THERMAL_CUTOFF = 103003; - //Tunnel temperature too high. Cannot execute job (Group = Safety, Category = Critical) - E_TUNNEL_HEATER_TEMPERATURE_TOO_HIGH = 103004; + //Tunnel thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical) + E_TUNNEL_THERMAL_CUTOFF = 103004; //Dyeing head thermal cutoff activated. Cannot execute job (Group = Safety, Category = Critical) E_DYEING_HEAD_THERMAL_CUTOFF = 103005; @@ -1357,14 +1357,17 @@ enum EventType //No Suction in dryer. Cannot execute job (Group = Safety, Category = Critical) E_DRYER_AIR_FLOW_SWITCH = 103009; - //Air filter not present. Cannot execute job (Group = Safety, Category = Critical) - E_AIR_FILTER_NOT_PRESENT = 103010; + //No circulation in dryer. Cannot execute job (Group = Safety, Category = Critical) + E_CIRCULATION_AIR_FLOW_SWITCH = 103010; - //Dryer temperature too high. Cannot execute job (Group = Safety, Category = Critical) - E_DRYER_HEATER_2_TEMPERATURE_TOO_HIGH = 103011; + //Dryer and tunnel thermal cutoffs activated. Cannot execute job (Group = Safety, Category = Critical) + E_DRYER_AND_TUNNEL_THERMAL_CUTOFF = 103011; - //Dryer temperature too high. Cannot execute job (Group = Safety, Category = Critical) - E_DRYER_HEATER_3_TEMPERATURE_TOO_HIGH = 103012; + //Dryer or tunnel thermal cutoff event happened. Cannot execute job (Group = Safety, Category = Critical) + E_TCO_EVENT_HAPPENED = 103012; + + //Air flow switch event happened (Group = Safety, Category = Warning) + E_AIR_FLOW_SWITCH_EVENT_HAPPENED = 103013; //Software error has occurred. Cannot execute job (Group = GeneralHardware, Category = Error) E_UNINTENDED_RESET = 104000; @@ -1669,6 +1672,12 @@ enum EventType //Temperature in lubricant is stabilizing. Cannot execute job (Group = Mixer, Category = Warning) E_LUBRICANT_OVERTEMPERATURE_B = 108046; + //IDS ambient temperature is too high. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_IDS_AMBIENT_1_OVERTEMPERATURE = 108047; + + //IDS ambient temperature is too high. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_IDS_AMBIENT_2_OVERTEMPERATURE = 108048; + //Dyeing head zone current is out of range. Cannot execute job (Group = DyeingHead, Category = Warning) E_DYEING_HEAD_ZONE_1_CURRENT_OUT_OF_RANGE = 109000; @@ -1762,23 +1771,32 @@ enum EventType //Dyeing head cleaner motor malfuncion. Cannot execute job (Group = DyeingHead, Category = Warning) E_DYEING_HEAD_CLEANER_MOTOR_MALFUNCTION = 110010; - //No suction. Cannot execute job. (Group = WasteHandlingSystem, Category = Error) - E_NO_SUCTION = 111000; + //Dryer push blower flow unstable. Cannot execute job. (Group = Dryer, Category = Error) + E_DRYER_PUSH_BLOWER_FLOW_UNSTABLE = 111000; + + //Dryer suction blower flow unstable. Cannot execute job (Group = Dryer, Category = Error) + E_DRYER_SUCTION_BLOWER_FLOW_UNSTABLE = 111001; + + //Tunnel push blower flow unstable. Cannot execute job (Group = DyeingHead, Category = Error) + E_TUNNEL_PUSH_BLOWER_FLOW_UNSTABLE = 111002; + + //Tunnel suction blower flow unstable. Cannot execute job (Group = DyeingHead, Category = Error) + E_TUNNEL_SUCTION_BLOWER_FLOW_UNSTABLE = 111003; - //Dryer blower flow is too low. Cannot execute job (Group = Dryer, Category = Warning) - E_DRYER_BLOWER_FLOW_TOO_LOW = 111001; + //IDS air conditioner malfunction. Cannot execute job (Group = InkDeliverySystem, Category = Warning) + E_IDS_AIR_CONDITIONER_MALFUNCTION = 111004; - //Tunnel blower flow is too low. Cannot execute job (Group = DyeingHead, Category = Warning) - E_TUNNEL_BLOWER_FLOW_TOO_LOW = 111002; + //Dryer push flow too low. Cannot execute job (Group = Dryer, Category = Error) + E_DRYER_PUSH_FLOW_TOO_LOW = 111005; - //Insufficient suction fron WHS. Cannot execute job (Group = WasteHandlingSystem, Category = Error) - E_INSUFFICIENT_WHS_SUCTION = 111003; + //Dryer suction flow too low. Cannot execute job (Group = Dryer, Category = Error) + E_DRYER_SUCTION_FLOW_TOO_LOW = 111006; - //Air filter is clogged. Cannot execute job (Group = WasteHandlingSystem, Category = Error) - E_AIR_FILTER_CLOGGED = 111004; + //Tunnel push flow too low. Cannot execute job (Group = DyeingHead, Category = Error) + E_TUNNEL_PUSH_FLOW_TOO_LOW = 111007; - //No circulation flow in dryer. Cannot execute job (Group = Dryer, Category = Error) - E_NO_CIRCULATION_FLOW_IN_DRYER = 111005; + //Tunnel suction flow too low. Cannot execute job (Group = DyeingHead, Category = Error) + E_TUNNEL_SUCTION_FLOW_TOO_LOW = 111008; //Pressure in @ ink line too high. Cannot execute job (Group = InkDeliverySystem, Category = Error) E_INK_LINE_1_PRESSURE_TOO_HIGH = 112000; @@ -1975,4 +1993,31 @@ enum EventType //Malfunction in @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error) E_INK_LINE_10_MID_TANK_MALFUNCTION = 112064; + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_16_MALFUNCTION = 112065; + + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_17_MALFUNCTION = 112066; + + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_18_MALFUNCTION = 112067; + + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_19_MALFUNCTION = 112068; + + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_20_MALFUNCTION = 112069; + + //Malfunction in @ ink pump. Cannot execute job (Group = InkDeliverySystem, Category = Error) + E_INK_PUMP_21_MALFUNCTION = 112070; + + //The @ tank level is low (Group = InkFillingSystem, Category = Warning) + E_INK_LINE_11_MID_TANK_LOW_LEVEL = 112071; + + //Failed to fill @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error) + E_INK_LINE_11_MID_TANK_FILL_TIMEOUT = 112072; + + //Malfunction in @ tank. Cannot execute job (Group = InkFillingSystem, Category = Error) + E_INK_LINE_11_MID_TANK_MALFUNCTION = 112073; + } |
