aboutsummaryrefslogtreecommitdiffstats
path: root/Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt')
-rw-r--r--Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt272
1 files changed, 0 insertions, 272 deletions
diff --git a/Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt b/Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt
deleted file mode 100644
index a4d81d3ba..000000000
--- a/Software/Stubs Collection/Procedures/EmbeddedParametersBuild.txt
+++ /dev/null
@@ -1,272 +0,0 @@
-using System;
-using System.Collections.Generic;
-using System.Collections.ObjectModel;
-using System.ComponentModel;
-using System.Linq;
-using System.Text;
-using System.Threading;
-using System.Threading.Tasks;
-using System.IO;
-using Google.Protobuf;
-using Tango.BL.Enumerations;
-using Tango.PMR.Stubs;
-using Tango.PMR.Diagnostics;
-using Tango.FSE.Common.Diagnostics;
-using Tango.PMR.EmbeddedParameters;
-using Tango.PMR.IO;
-using Tango.FSE.Procedures;
-
-
-public class Cleaning
-{
- [Description("Actuator Going up time")]
- public int Tup;
- [Description("Actuator Wait up time")]
- public int Tdelay1;
- [Description("Actuator Wait Down time")]
- public int Tdelay2;
-}
-public class Advanced
-{
- [Description("Automatic heating on machine StartUp")]
- public bool InitialHeating;
- [Description("Waste pressure buildup factor")]
- public int WFCF;
- [Description("Auto fill mode on/off")]
- public bool Autofill;
-}
-
-public class Program
-{
- public void OnExecute(IProcedureContext context)
- {
- string description = "";
- context.AddResult(ResultType.Passed, "My Value Name", "Test for this value has passed.");
- ConfigurationParameters configurationParameters = new ConfigurationParameters();
-
- bool AdvancedParams = context.GetInput<bool>("AdvancedParameters");
- Advanced Advancedparam = new Advanced();
- Advancedparam.InitialHeating = true;
- Advancedparam.WFCF = 40;
- Advancedparam.Autofill = true;
- if (AdvancedParams == true)
- Advancedparam = context.RequestUserInputFor<Advanced>(Advancedparam,"Advanced parameters input Required","Please fill in the form");
- description += "Version 1.5.3.3";
- configurationParameters.BreakSensorLimit = 10;
-
- //how many samples to collect in diagnostics before sending
- configurationParameters.DiagnosticCollectionLimit = 1;
-
- //how many consecutive readout before declaring DC over/underheat alarm
- configurationParameters.OverHeatCountLimit = 3;
- configurationParameters.UnderHeatCountLimit = 3;
-
- // time of motor activity before opening the valve or after closing the valve, in milliseconds
- configurationParameters.CloseValveTimeout = 20;
- configurationParameters.OpenValveTimeout = 20;
-
- //backlash after filling - target pressure, timoeout, time staps (speed will be added in general parameters)
- configurationParameters.InitialDispenserPressure = 3.85; //used for initial pre-run maximal pressure
- configurationParameters.InitialDispenserTimeout = 120000; ////used for initial pre-run target number of steps
- configurationParameters.InitialDispenserTimeLag = 100;
- description = description+" "+configurationParameters.InitialDispenserPressure+"-"+configurationParameters.InitialDispenserTimeout/1000;
-
- //job prepare - build pressure in dispensers - target pressure, timoeout, time staps, speed
- configurationParameters.DispenserBuildPressureSpeed = 950; //no more than 1000
- configurationParameters.DispenserBuildPressureLimit = 0.85;
- configurationParameters.DispenserBuildPressureTimeout = 420000;
- configurationParameters.DispenserBuildPressureLag = 100;
- description = description+" T "+configurationParameters.DispenserBuildPressureTimeout/1000;
-
- //temperature band 1000 = 100% - thresholds for job start around target temprature - AC
- configurationParameters.ACHeatersLowerOperationLimit = 995;
- configurationParameters.ACHeatersUpperOperationLimit = 1005;
-
- //temperature band 1000 = 100% - thresholds for job start around target temprature - DC
- configurationParameters.DCHeatersLowerOperationLimit = 978;
- configurationParameters.DCHeatersUpperOperationLimit = 1005;
-
- // mid tank reading offset to add to the readout (OBSOLETE!)
- configurationParameters.MidTankPressureCorrection = 0.0;
-
- //waste factor for intersegment pressure building
- configurationParameters.DispenserPresegmentWFCF = Advancedparam.WFCF;
- description = description+" WF"+configurationParameters.DispenserPresegmentWFCF;
-
- //how much time to start the WFCF process (pressure buildup) before segment start
- configurationParameters.IDSPreSegmentWFCFTimeBeforeSegment = 12000;
-
- //flag: start heaters according to saved process parameters upon init?
- configurationParameters.StartHeatingOnInitSequence = Advancedparam.InitialHeating;
-
- // current test for the heaters - alarm thresholds
- configurationParameters.CurrentAlarmLowLimit = 0.78;
- configurationParameters.CurrentAlarmHighLimit = 1.07;
-
- //currently not in use
- configurationParameters.IDSSegmentRefillTimeout = 5000;
- configurationParameters.IDSPreSegmentBuildupTime = 5000;
- //cleaning!!!!!!!!!!
- configurationParameters.IDSCleaningSpeed = 800;
- configurationParameters.IDSCleaningStopBeforeSegmentTime = 10000; //end of presegemnt
- configurationParameters.IDSCleaningStartSprayPreSegmentTime =2000; //beginning of presegment
- description = description+" Cl"+configurationParameters.IDSCleaningStopBeforeSegmentTime/1000+"-"+configurationParameters.IDSCleaningStartSprayPreSegmentTime/1000;
-
- bool SetCleaning = context.GetInput<bool>("SetCleaningValues");
- Cleaning Clean = new Cleaning();
- Clean.Tup = 10;
- Clean.Tdelay1 = 98;
- Clean.Tdelay2 = 198;//300 milli up, stay 1 sec, stay down 2 sec
- if (SetCleaning == true)
- Clean = context.RequestUserInputFor<Cleaning>(Clean,"Cleaning Input Required","Please fill in the form");
-
- // Tup = LeftRockerSpeed/100;
- // Tdelay1 = LeftRockerSpeed%100;
- // Tdelay2 = RightRockerSpeed;
- int LeftRockerSpeed = Clean.Tup*100+Clean.Tdelay1;
- int RightRockerSpeed = Clean.Tdelay2;
-
- configurationParameters.IDSLeftCleaningMotorSpeed = LeftRockerSpeed;
- configurationParameters.IDSRightCleaningMotorSpeed = RightRockerSpeed;
- description = description+"-"+Clean.Tup+"."+Clean.Tdelay1+"."+Clean.Tdelay2;
-
- configurationParameters.SwitchToIdleTimeinSeconds = 3600;
- configurationParameters.IdleDrierTemperature = 80;
- configurationParameters.IdleHeadTemperature = 80;
- configurationParameters.IdleMixerTemperature = 0;
- configurationParameters.PowerOffTemperatureLimit = 60;
-
- //general parameters, ORDER MUST BE PRESERVED!!!!
- //check the dispensers hard limit alarms
- /*1*/
- Double checkHardLimitAlarms = new Double();
- checkHardLimitAlarms = 1.0;
- configurationParameters.GeneralParameters.Add(checkHardLimitAlarms);
-
- /*2*/
- Double checkCurrentAlarms = new Double();
- checkCurrentAlarms = 0.0;
- configurationParameters.GeneralParameters.Add(checkCurrentAlarms);
- //check the tamper alarms
-
- /*3*/
- Double checkTamperAlarms = new Double();
- checkTamperAlarms = context.GetInput<double>("CheckTampers");
- configurationParameters.GeneralParameters.Add(checkTamperAlarms);
-
- /*4*/
- Double checkMotorAlarms = new Double();
- checkMotorAlarms = 1.0;
- configurationParameters.GeneralParameters.Add(checkMotorAlarms);
- description = description+"-Cur"+checkCurrentAlarms+"Tamp"+checkTamperAlarms+"Mot"+checkMotorAlarms;
-
- /*5*/
- Double WinderBackToBaseTime = new Double();
- WinderBackToBaseTime = 820.0;
- configurationParameters.GeneralParameters.Add(WinderBackToBaseTime);
- /*6*/
- Double DispenserInitialPressureSpeed = new Double();
- DispenserInitialPressureSpeed = 1050.0;
- configurationParameters.GeneralParameters.Add(DispenserInitialPressureSpeed);
-
- /*7*/
- Double SetDiagnosticMode = new Double();
- SetDiagnosticMode = 3.0;
- configurationParameters.GeneralParameters.Add(SetDiagnosticMode);
-
- /*8*/
- Double SetAutoFill = new Double();
- SetAutoFill = 3.0;
- if (Advancedparam.Autofill == false)
- SetAutoFill = 0.0;
- configurationParameters.GeneralParameters.Add(SetAutoFill);
- description = description+"-AF"+SetAutoFill+"DI"+SetDiagnosticMode;
- /*9*/
- double PowerOffDisableCleaning = new Double();
- PowerOffDisableCleaning = 0.0;
- configurationParameters.GeneralParameters.Add(PowerOffDisableCleaning);
- /*10*/
- double SublimationBlowTime = new Double();
- SublimationBlowTime = 30.0;
- configurationParameters.GeneralParameters.Add(SublimationBlowTime);
- /*11*/
- double AllowedRangeForHeadBlowerDeviation = new Double();
- AllowedRangeForHeadBlowerDeviation = 7;
- configurationParameters.GeneralParameters.Add(AllowedRangeForHeadBlowerDeviation);
- /*12*/
- double AllowedRangeForWasteBlowerDeviation = new Double();
- AllowedRangeForWasteBlowerDeviation = 20;
- configurationParameters.GeneralParameters.Add(AllowedRangeForWasteBlowerDeviation);
- /*13*/
- double Voltage_Hysteresis = new Double();
- Voltage_Hysteresis = 4;
- configurationParameters.GeneralParameters.Add(Voltage_Hysteresis);
- /*14*/
- double Head_Blower_Calculation_C = new Double();
- Head_Blower_Calculation_C = 0.242;
- configurationParameters.GeneralParameters.Add(Head_Blower_Calculation_C);
- /*15*/
- double Head_Blower_Calculation_B = new Double();
- Head_Blower_Calculation_B = -0.134;
- configurationParameters.GeneralParameters.Add(Head_Blower_Calculation_B);
- description = description+"-C"+Head_Blower_Calculation_C+"-B"+Head_Blower_Calculation_B;
-
- configurationParameters.Description = description;
-
-
- //configurationParameters = context.RequestUserInputFor<ConfigurationParameters>(configurationParameters,"ConfigurationParameters Input Required","Please fill in the form");
- /*Directory.CreateDirectory ("C:/Temp");
- File.WriteAllBytes("C:/temp/EmbParam.cfg",configurationParameters.ToBytes());
-
- byte[] fileBytes1 = File.ReadAllBytes("C:/temp/EmbParam.cfg");*/
- byte[] fileBytes = configurationParameters.ToBytes();
-
-
- var config = ConfigurationParameters.Parser.ParseFrom(fileBytes);
-
- context.Write( config);
- Thread.Sleep(1000);
-
-
- context.Write("\n\n Deleting old file");
-
- DeleteRequest deleteRequest = new DeleteRequest();
- deleteRequest.Path = "SYSINFO//EmbParam.cfg";
- deleteRequest.Attribute = Tango.PMR.IO.FileAttribute.Unspecified;
- DeleteResponse response5 = context.Send<DeleteResponse>(deleteRequest);
-
-
- Thread.Sleep(1000);
- context.Write("\n\n Loading new file file");
-
- FileUploadRequest fileUploadRequest = new FileUploadRequest();
- fileUploadRequest.Path = "SYSINFO//EmbParam.cfg";
- fileUploadRequest.Length = (int)fileBytes.Length;
- FileUploadResponse response2 = context.Send<FileUploadResponse>(fileUploadRequest);
- Thread.Sleep(1000);
- long chunk_size = response2.MaxChunkLength;
-
- context.Write("Chunk size "+ chunk_size + " file size "+ fileBytes.Length +"\n\n");
- if (chunk_size < fileBytes.Length)
- {
- context.AddResult(ResultType.Failed, "Chunk size too small", chunk_size);
- }
- else
- {
- FileChunkUploadRequest fileChunkUploadRequest = new FileChunkUploadRequest();
- fileChunkUploadRequest.UploadID = response2.UploadID;
- fileChunkUploadRequest.Buffer = ByteString.CopyFrom(fileBytes);
- var response3 = context.Send<FileChunkUploadResponse>(fileChunkUploadRequest);
-
- //if (response3.
-
- // activating the new file
- ProgressRequest progressRequest = new ProgressRequest();
- progressRequest.Amount = 0xCD;
- progressRequest.Delay = 0xCD;
- var response1 = context.Send<ProgressResponse>(progressRequest);
- context.AddResult(ResultType.Passed, "parameters loaded", chunk_size);
- }
-
- }
-} \ No newline at end of file