| Commit message (Expand) | Author | Age | Files | Lines |
| * | PNR file updated in embedded. | Shlomo Hecht | 2019-02-19 | 2 | -2/+0 |
| * | Version 1.3.7.3 INIT SEQUENCE - starts heating!. safe control remove in callb... | Shlomo Hecht | 2019-02-18 | 3 | -1/+44 |
| * | version 1.3.7.1: cancel cone presence checks, load dancer middle point from f... | Shlomo Hecht | 2019-02-14 | 1 | -2/+2 |
| * | experimental code for improved control - not tested yet (commented out) | Shlomo Hecht | 2019-02-10 | 1 | -5/+12 |
| * | Version 1.3.6.2 load dancer parameters, othe rsw parameters | Shlomo Hecht | 2019-02-10 | 1 | -0/+48 |
| * | merge | Shlomo Hecht | 2019-02-07 | 2 | -1/+29 |
| |\ |
|
| | * | update the logic of Machine Leds (using PWM) | Avi Levkovich | 2019-02-07 | 2 | -1/+29 |
| * | | reboot after load | Shlomo Hecht | 2019-02-07 | 1 | -26/+0 |
| |/ |
|
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/_git/Tango | Avi Levkovich | 2019-02-04 | 1 | -6/+7 |
| |\ |
|
| | * | bug correction in control - killed app | Shlomo Hecht | 2019-02-04 | 1 | -6/+7 |
| * | | Add temporary function to test the breathing leds | Avi Levkovich | 2019-02-04 | 1 | -0/+2 |
| |/ |
|
| * | try improved real time handling in control - not tested yet | Shlomo Hecht | 2019-02-02 | 1 | -10/+31 |
| * | Add new functions: | Avi Levkovich | 2019-01-31 | 1 | -1/+1 |
| * | Version 1.3.5.4: Heaters connection fixed. some job end problem removed. IDS ... | Shlomo Hecht | 2019-01-30 | 2 | -32/+32 |
| * | Version 1.3.5.3: IDS handling, control track and fixing, and other changes. | Shlomo Hecht | 2019-01-29 | 1 | -0/+3 |
| * | 1.3.5.0 changes | Shlomo Hecht | 2019-01-24 | 2 | -6/+2 |
| * | Version 1.3.2.0 - Machine Studio 4 - new inerface (alarms). new over/under te... | Shlomo Hecht | 2019-01-15 | 2 | -8/+8 |
| * | stop initial dc heating at 97.8% because of rampup rate. refresh midtank level. | Shlomo Hecht | 2019-01-10 | 1 | -4/+4 |
| * | Version 1.3.1.1 changes | Shlomo Hecht | 2019-01-09 | 3 | -166/+36 |
| * | heater - turn off when above temperature on initial heating | Shlomo Hecht | 2019-01-03 | 1 | -0/+7 |
| * | Winder bugs. improved trace, improved control (callback invoked after time re... | Shlomo Hecht | 2018-12-17 | 2 | -7/+30 |
| * | Version 1.3.0.2 Reset Cause in log, remove some logs, improve memory on alarm... | Shlomo Hecht | 2018-12-17 | 2 | -13/+160 |
| * | Version 1.2.1.0: Support for new dispensers, comments removed, diagnostics su... | Shlomo Hecht | 2018-12-12 | 1 | -2/+0 |
| * | advanced PID in thread and heaters - use only with modified congiguration | Shlomo Hecht | 2018-11-29 | 2 | -0/+40 |
| * | fix PID in heaters. waste tank valve in intersegment (bug #323) | Shlomo Hecht | 2018-11-28 | 1 | -1/+1 |
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2018-11-22 | 1 | -1/+1 |
| |\ |
|
| | * | merge | Avi Levkovich | 2018-11-22 | 1 | -3/+13 |
| | |\ |
|
| | * | | Add JTAG_VME | Avi Levkovich | 2018-11-22 | 1 | -1/+1 |
| * | | | file operation stub and handling | Shlomo Hecht | 2018-11-22 | 1 | -0/+1 |
| | |/
|/| |
|
| * | | many logs. improve job handling and IDS. NEW WINDER ALGORITHM (Interrupts) | Shlomo Hecht | 2018-11-15 | 1 | -3/+10 |
| * | | reset control with eNoControl value | Shlomo Hecht | 2018-11-11 | 1 | -0/+3 |
| |/ |
|
| * | Heaters PID enabled per configuration. USB reinitialized. new HW handling wit... | Shlomo Hecht | 2018-11-05 | 1 | -4/+4 |
| * | small corrections | Shlomo Hecht | 2018-10-25 | 2 | -97/+38 |
| * | IDS - do not switch off valve between segments if used in the next segment. S... | Shlomo Hecht | 2018-10-22 | 2 | -1/+78 |
| * | thread debug. diagnostics heaters state | Shlomo Hecht | 2018-10-14 | 1 | -2/+2 |
| * | PMR for version 3.5. | Shlomo Hecht | 2018-10-11 | 1 | -2/+2 |
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2018-10-10 | 1 | -17/+33 |
| |\ |
|
| | * | heater PID - need to test dryer! | Shlomo Hecht | 2018-10-10 | 1 | -2/+2 |
| | * | update the speed sensor and change the sampalling to 100msec | Shlomo Hecht | 2018-10-09 | 1 | -19/+35 |
| * | | keep alive implementation | Shlomo Hecht | 2018-10-10 | 1 | -0/+3 |
| |/ |
|
| * | Heater state in diagnostics. new error codes. | Shlomo Hecht | 2018-10-04 | 1 | -0/+1 |
| * | priority for screw run commands (set max speed and move) | Shlomo Hecht | 2018-09-17 | 2 | -2/+37 |
| * | tests for the winder | Shlomo Hecht | 2018-09-17 | 2 | -2/+39 |
| * | reduce polling of motor status. changed speed sensor to 100msec | Shlomo Hecht | 2018-09-16 | 2 | -8/+16 |
| * | fan tacho interface | Shlomo Hecht | 2018-09-06 | 2 | -1/+3 |
| * | Update the Read_Fans_Tacho function to read 4 x small Fans (Rotation indicat... | Avi Levkovich | 2018-09-06 | 1 | -2/+6 |
| * | Motor Status read for alarm handling. | Shlomo Hecht | 2018-09-06 | 1 | -0/+5 |
| * | Change the Speed Sensor velocity units to float [cm/sec] | Avi Levkovich | 2018-08-27 | 2 | -3/+3 |
| * | reduce motorconfig size. remove graphic lib. alarm handling does not stop the... | Shlomo Hecht | 2018-08-16 | 1 | -1/+1 |
| * | Improve temperature calculation time. alarm handling bugs, DC heater possible... | Shlomo Hecht | 2018-08-15 | 2 | -11/+8 |