* preparations for light colors and cosmeticsShlomo Hecht2020-11-191-0/+1
|
* Version 1.4.6.19 new RML parameters, tension spring handling, some bug fixingShlomo Hecht2020-03-251-1/+1
|
* update diagnostics blower on change. fix process parameters handling, add ↵Shlomo Hecht2020-02-131-1/+2
| | | | new head current readings to diagnostics
* header fixShlomo Hecht2020-02-031-0/+1
|
* device information and time stamps on diagnosticsShlomo Hecht2020-01-191-0/+1
|
* improvements and debuggingShlomo Hecht2019-12-121-0/+2
|
* Version 1.4.3.85 diagnstics levels set in config params. machine status.Shlomo Hecht2019-08-181-1/+9
|
* Version 1.4.3.41 critical update in alarm handling. created some problem in ↵Shlomo Hecht2019-08-091-0/+1
| | | | HW init
* 1.3.5.0 changesShlomo Hecht2019-01-241-0/+1
| | | | | | | | | | | | | | | | | | | ==================================== 1. preparations for keeping data in internal flash 2. keep applicative data in external flash: software parameters, dispensers data, etc. 3. moved to new alarms definitions, tamper alarms, improved temperature alarms, cone presence alarm, 4. support for Machine Studio 4 5. some tests for memory allocations 6. thread load proto code 7. Hardware: doors tampering switches, drier fan, blower PWM control, new backplane support, new motor drivers support, 8. FPGA jtag code loading 9. Heaters: alarms on set temperature band. test facilities. 10. motors - additional complex actions for thread load support. new drivers support 11. preparations for control debugging 12. read motor status and mid tank level 13. collect and store dispenser usage data 14. IDS - controlled operation of motor and valve. backlash movement after refill 15. bug fixes in job handling
* Version 1.1.5.4 fix alarm handling bug, improve valve handling and reports, ↵Shlomo Hecht2018-12-051-0/+1
| | | | add vavle widget support. Thread advanced PID!
* prevent sending diagnostics message if the prev one did not run. improve windingShlomo Hecht2018-11-131-0/+1
|
* homing/ jogging only for configured motors. default blower value 3000 millivoltShlomo Hecht2018-08-201-0/+1
|
* blower support, logs in dispensers and heaters, diagnstic improvedShlomo Hecht2018-08-071-0/+7
|
* Speed sensor placeholders. new diagnostics approachShlomo Hecht2018-08-011-1/+2
|
* Diagnostics: motors jogging and homing, disoensers jogging and homingShlomo Hecht2018-07-291-0/+34