| Commit message (Collapse) | Author | Age | Files | Lines | ||
|---|---|---|---|---|---|---|
| ... | ||||||
| * | use the new IFS_AVAILABILITY enum | Avi Levkovich | 2020-07-27 | 1 | -1/+1 | |
| | | ||||||
| * | loading improved, actoator relocated. waste alarms | Shlomo Hecht | 2020-07-26 | 1 | -1/+4 | |
| | | ||||||
| * | some small changes, mostly in drier loading | Shlomo Hecht | 2020-07-23 | 2 | -5/+12 | |
| | | ||||||
| * | fixes in h file waste_ex.h insted of waste.h | Ronen Sberlo | 2020-07-20 | 2 | -2/+2 | |
| | | ||||||
| * | fix thread PID handling on job start. cleaning improved. stub for watchdog added | Shlomo Hecht | 2020-07-15 | 1 | -4/+5 | |
| | | ||||||
| * | Embedded SW Release note - Version 1.4.6.34 - Pack 2+ | Shlomo Hecht | 2020-06-29 | 1 | -5/+5 | |
| | | | | | | | | | | | | | | | | ============================================================= Validate IFS and cartridge location on manual waste handling - bug #3033 better handling of powerstep01 configuration and motors clocks waste level: logs, fixed reading during waste filling, fix PT100 reading in WHS //important, OK improve diespensers reading in I2C timing //important OK alarm handling: fix report (mid tank empty) diagnostics - waste level in liters Heating and process - avoid activating all heaters at once. tested for flat head. Heating - remove alarms when colling dwn due to change of RML or idle mode Thread - improve feeder tension handling system: hold initalization process after 3 failures to enable code / parameters change and debugging | |||||
| * | minor changes - remove warnings + move global parameters from main to ↵ | Avi Levkovich | 2020-06-23 | 1 | -0/+1 | |
| | | | | | FPGA_Comm.h | |||||
| * | Check IFS Availability+ change Waste Tank Level from ml to litter | Avi Levkovich | 2020-06-23 | 1 | -1/+1 | |
| | | ||||||
| * | update | Avi Levkovich | 2020-06-17 | 2 | -93/+166 | |
| | | ||||||
| * | new powerstep parameters, better handling of FPGA loading and tension parameters | Shlomo Hecht | 2020-06-14 | 1 | -0/+11 | |
| | | ||||||
| * | Merge with Avi's pressure sensor | Shlomo Hecht | 2020-06-11 | 1 | -4/+11 | |
| | | ||||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2020-06-11 | 1 | -7/+18 | |
| |\ | ||||||
| | * | Add support of ARC pressure sensor board | Avi Levkovich | 2020-06-11 | 1 | -7/+18 | |
| | | | ||||||
| * | | Version 1.4.6.31: init failures - stop init until new version loaded / FSE ↵ | Shlomo Hecht | 2020-06-11 | 1 | -1/+2 | |
| |/ | | | | arrives. read / write main CPU data (embedded parameters); VOC read to diagnostics; | |||||
| * | init default whs PID | Shlomo Hecht | 2020-06-10 | 1 | -0/+21 | |
| | | ||||||
| * | fixing some bugs in version 30 | Shlomo Hecht | 2020-06-09 | 1 | -1/+16 | |
| | | ||||||
| * | blower control improved. diagnostics for system tests | Shlomo Hecht | 2020-06-02 | 1 | -22/+41 | |
| | | ||||||
| * | fix head identification; remove adc interrupt | Shlomo Hecht | 2020-06-01 | 2 | -76/+146 | |
| | | ||||||
| * | Version 1.4.6.29 feeder dancer tension, loading arm homing, buttons fixed, | Shlomo Hecht | 2020-05-27 | 1 | -16/+76 | |
| | | ||||||
| * | machine status with spool, WHS EEPROM interface, cartridges state in ↵ | Shlomo Hecht | 2020-05-25 | 1 | -2/+22 | |
| | | | | | diagnostics, | |||||
| * | fixes for thread loading, VOC and waste handling | Shlomo Hecht | 2020-05-25 | 1 | -2/+2 | |
| | | ||||||
| * | fix current alarms (PP only). RFID stubs, | Shlomo Hecht | 2020-05-20 | 1 | -8/+10 | |
| | | ||||||
| * | cleaning job bug, prevent reporting dispenser homing for auto homing. drier ↵ | Shlomo Hecht | 2020-05-18 | 1 | -1/+11 | |
| | | | | | fan / whs fan alarms | |||||
| * | new protobuf applied | Shlomo Hecht | 2020-05-12 | 1 | -12/+10 | |
| | | ||||||
| * | fix flash problems, whs problems | Shlomo Hecht | 2020-05-11 | 1 | -2/+2 | |
| | | ||||||
| * | bug fixes and investigations. IFS brushstop closing, waste tank diagnostics, ↵ | Shlomo Hecht | 2020-05-10 | 1 | -0/+4 | |
| | | | | | heaters hangout handling | |||||
| * | fix some small things. some logs added | Shlomo Hecht | 2020-05-07 | 1 | -0/+11 | |
| | | ||||||
| * | Version 1.4.6.23: Power up interface implemented, WHS improvements, ↵ | Shlomo Hecht | 2020-05-05 | 1 | -21/+29 | |
| | | | | | diagnostics bug fix | |||||
| * | support init state messages and some bug fixed | Shlomo Hecht | 2020-05-03 | 1 | -0/+7 | |
| | | ||||||
| * | Version 1.4.6.22 small fixes | Shlomo Hecht | 2020-04-27 | 1 | -6/+14 | |
| | | ||||||
| * | motor homing continuous response. ids test for lost time | Shlomo Hecht | 2020-04-23 | 1 | -26/+116 | |
| | | ||||||
| * | fix drier lid actions for powerstep | Shlomo Hecht | 2020-04-02 | 2 | -6/+12 | |
| | | ||||||
| * | handling of safety heating tests, dancers position | Shlomo Hecht | 2020-04-02 | 1 | -1/+1 | |
| | | ||||||
| * | Version 1.4.6.19 new RML parameters, tension spring handling, some bug fixing | Shlomo Hecht | 2020-03-25 | 2 | -8/+3 | |
| | | ||||||
| * | Version 1.4.6.18 fix mkdir failure FR_EXISTS | Shlomo Hecht | 2020-03-22 | 1 | -2/+2 | |
| | | ||||||
| * | sime fixes for Rapid 2 ( new LTFU) | Shlomo Hecht | 2020-03-15 | 1 | -5/+5 | |
| | | ||||||
| * | Version 1.4.6.17 - PACK 1. (support for new TFU and bug fixes) | Shlomo Hecht | 2020-03-12 | 1 | -0/+10 | |
| | | ||||||
| * | fix error reporting in powerbuff | Shlomo Hecht | 2020-03-08 | 2 | -0/+3 | |
| | | ||||||
| * | Version 1.4.6.16 handle rockers PPC homing request, fix FFS semaphore issue | Shlomo Hecht | 2020-03-05 | 1 | -0/+20 | |
| | | ||||||
| * | merge conflicts | Avi Levkovich | 2020-03-01 | 3 | -12/+28 | |
| |\ | ||||||
| | * | Version 1.4.6.14 - new RML | Shlomo Hecht | 2020-02-27 | 1 | -4/+4 | |
| | | | ||||||
| | * | fix current alarm when PID is active. start power off sequence from tablet | Shlomo Hecht | 2020-02-25 | 1 | -2/+16 | |
| | | | ||||||
| | * | small fixes | Shlomo Hecht | 2020-02-20 | 1 | -5/+7 | |
| | | | ||||||
| | * | bug fixes before version 1.4.6.12 | Shlomo Hecht | 2020-02-19 | 1 | -1/+1 | |
| | | | ||||||
| * | | Head type identification + fix head heaters current calculation | Avi Levkovich | 2020-03-01 | 1 | -0/+1 | |
| |/ | ||||||
| * | preparations and fixes for 1.4.6.12 | Shlomo Hecht | 2020-02-18 | 1 | -6/+11 | |
| | | ||||||
| * | alarm handling flags n EEPROM, machine temperature debuging | Shlomo Hecht | 2020-02-16 | 1 | -0/+1 | |
| | | ||||||
| * | update diagnostics blower on change. fix process parameters handling, add ↵ | Shlomo Hecht | 2020-02-13 | 3 | -47/+210 | |
| | | | | | new head current readings to diagnostics | |||||
| * | Veraion 1.4.6.10 improve current reading, fir I2C interface, improve (?) ↵ | Shlomo Hecht | 2020-02-12 | 1 | -2/+11 | |
| | | | | | task priorities | |||||
| * | improve powerstep and reglar, new process params, start of power management | Shlomo Hecht | 2020-02-09 | 1 | -0/+17 | |
| | | ||||||