| Commit message (Collapse) | Author | Age | Files | Lines | ||
|---|---|---|---|---|---|---|
| ... | ||||||
| * | fix internal overheat alarms | Shlomo Hecht | 2019-10-11 | 1 | -1/+1 | |
| | | ||||||
| * | heater print bug - spike and low temp not handled | Shlomo Hecht | 2019-10-11 | 1 | -3/+17 | |
| | | ||||||
| * | minor bugs | Shlomo Hecht | 2019-10-10 | 1 | -0/+3 | |
| | | ||||||
| * | handle safety alarms, log winder better. | Shlomo Hecht | 2019-09-22 | 1 | -1/+1 | |
| | | ||||||
| * | bug in heaters current alarms | Shlomo Hecht | 2019-09-18 | 1 | -0/+1 | |
| | | ||||||
| * | Version 1.4.4.8: stop thread loading, bypass safety on dispenser homing and ↵ | Shlomo Hecht | 2019-09-16 | 1 | -5/+5 | |
| | | | | | priming | |||||
| * | machine status, prevent job when active (bug), heater prints, FPGA Version files | Shlomo Hecht | 2019-09-15 | 1 | -0/+8 | |
| | | ||||||
| * | USE BOTH HEATERS IN DRYER! machine calibration data. rfid tag content ↵ | Shlomo Hecht | 2019-09-09 | 1 | -3/+10 | |
| | | | | | PPC<==>RFID transfer. | |||||
| * | Version 1.4.3.85 diagnstics levels set in config params. machine status. | Shlomo Hecht | 2019-08-18 | 1 | -5/+5 | |
| | | ||||||
| * | fixes in waste/ink | Shlomo Hecht | 2019-08-15 | 1 | -1/+1 | |
| | | ||||||
| * | Version 1.4.3.0 Embedded SW Release note - Version 1.4.3.0 | Shlomo Hecht | 2019-08-01 | 1 | -7/+44 | |
| | | | | | | | | | | | | | | | | | | | | | ============================================================= System: File system protection + improvements Keep critical data on MCU EEPROM Procedures: Thread load fix and coordinate the amount of thread in drier to the distance to spool length. Dispensers flow control stage 2a - maintain pressure during presegment Modules: Enclosure temperature alarms Secondary waste pump Dispensers state info Heaters protection improved Diagnostics data - full data, full speed for now Thread - fix length calculation Process: Cleaning ready for integration | |||||
| * | Version 1.4.2.5 firmware upgrade works, improved thread load. (works????) | Shlomo Hecht | 2019-07-24 | 1 | -5/+4 | |
| | | ||||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2019-07-23 | 1 | -2/+8 | |
| |\ | ||||||
| | * | update the Head PT100 ADC module | Avi Levkovich | 2019-07-21 | 1 | -2/+8 | |
| | | | ||||||
| * | | Version 1.4.2.5 store data in EEPROM, thread loading, IDS datat store, IDS ↵ | Shlomo Hecht | 2019-07-23 | 1 | -0/+80 | |
| |/ | | | | prepare with reduced ink usage | |||||
| * | Version 1.4.2.2 report filters introduced, improved flash handling. ↵ | Shlomo Hecht | 2019-07-15 | 1 | -56/+56 | |
| | | | | | improved and simplified dispenser location. improved config parameters handling | |||||
| * | Version 1.4.1.1 improve watchdog/DFU handling (works, not great) | Shlomo Hecht | 2019-06-30 | 1 | -2/+2 | |
| | | ||||||
| * | Embedded SW Release note - Version 1.4.1.0 | Shlomo Hecht | 2019-06-27 | 1 | -10/+31 | |
| | | | | | | | | | | ============================================================= Move to length calculation FROM PULLER fix intersegment handling FLASH - rebuilt. using data from flash instead of FFS DFU fixed. Heaters handling fixed. job starts only in proximity to requested temperature | |||||
| * | preparation for sample winding, preparation for work with FLASH instead of FFS | Shlomo Hecht | 2019-06-17 | 1 | -2/+3 | |
| | | ||||||
| * | Version 1.4.0.7 Heaters PID on band, does not check motor status | Shlomo Hecht | 2019-06-04 | 1 | -8/+8 | |
| | | ||||||
| * | heaters pid rethinking - not compiling! | Shlomo Hecht | 2019-06-03 | 1 | -8/+10 | |
| | | ||||||
| * | PID - fabs() enabled small integral values. empty waste indication. | Shlomo Hecht | 2019-05-19 | 1 | -0/+2 | |
| | | ||||||
| * | heater trace | Shlomo Hecht | 2019-05-15 | 1 | -1/+13 | |
| | | ||||||
| * | Version 1.3.10.1 Support for lubricant valve in tech board. double reporting ↵ | Shlomo Hecht | 2019-05-14 | 1 | -1/+3 | |
| | | | | | bug, winding - small change. keepalive failure restarts usb driver. some traces. | |||||
| * | version 1.3.9.9 IDS: build pressure to waste on job prepare. Heaters: do not ↵ | Shlomo Hecht | 2019-05-07 | 1 | -7/+8 | |
| | | | | | restart heating on new setup if set temperature had not changed. lubricant vavle workaround | |||||
| * | Version 1.3.9.8 Removed unreliable alarms and load. removed pressure build ↵ | Shlomo Hecht | 2019-05-07 | 1 | -0/+1 | |
| | | | | | on machine start | |||||
| * | fix job length bug. read screw encoder. better logging in IDS | Shlomo Hecht | 2019-05-02 | 1 | -0/+1 | |
| | | ||||||
| * | MERGE. | Roy Ben-Shabat | 2019-05-02 | 1 | -3/+3 | |
| | | ||||||
| * | small change | Shlomo Hecht | 2019-04-30 | 1 | -1/+1 | |
| | | ||||||
| * | mid tank should not stop a job | Shlomo Hecht | 2019-04-30 | 1 | -2/+3 | |
| | | ||||||
| * | Version 1.3.9.32 reduced diagnostics. new ITMA screens. heating improved. ↵ | Shlomo Hecht | 2019-04-30 | 1 | -14/+34 | |
| | | | | | lubricant handled better | |||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/_git/Tango | Avi Levkovich | 2019-04-29 | 1 | -1/+1 | |
| |\ | ||||||
| | * | dispenser dtat writing disabled (potential disconnect cause). heaters bug. | Shlomo Hecht | 2019-04-29 | 1 | -1/+1 | |
| | | | ||||||
| * | | Add brackets to defines with calculation | Avi Levkovich | 2019-04-29 | 1 | -1/+1 | |
| |/ | ||||||
| * | fix bug in heaters when drier heaters are above 250 | Shlomo Hecht | 2019-04-17 | 1 | -5/+8 | |
| | | ||||||
| * | bug fixes in heaters and IDS | Shlomo Hecht | 2019-04-17 | 1 | -5/+11 | |
| | | ||||||
| * | version 1.3.8.51: bug fix in winder; many fixes in heaters | Shlomo Hecht | 2019-04-17 | 1 | -17/+54 | |
| | | ||||||
| * | minor changes | Shlomo Hecht | 2019-04-16 | 1 | -1/+1 | |
| | | ||||||
| * | Version 1.3.8.49 dispenser data request, added config params (support ↵ | Shlomo Hecht | 2019-04-14 | 1 | -1/+1 | |
| | | | | | pending). improvements in heating control, automatic refill at the end of job | |||||
| * | bug fix in control (uint16 timimg - not good for large segments) and heaters ↵ | Shlomo Hecht | 2019-04-11 | 1 | -6/+9 | |
| | | | | | (increase band, handle job end) | |||||
| * | fix a bug in internal alarm clear | Shlomo Hecht | 2019-04-10 | 1 | -2/+1 | |
| | | ||||||
| * | heater disaster handling | Shlomo Hecht | 2019-04-10 | 1 | -22/+69 | |
| | | ||||||
| * | MERGE | Roy Ben Shabat | 2019-04-09 | 1 | -61/+105 | |
| | | ||||||
| * | small improbvements in job handling and job end. preparations for log ↵ | Shlomo Hecht | 2019-04-01 | 1 | -4/+4 | |
| | | | | | distributors setup | |||||
| * | Version 1.3.8.12 printing function calls with segments info. ids - no ↵ | Shlomo Hecht | 2019-03-27 | 1 | -6/+6 | |
| | | | | | valves. improved winding. dispensers pressure build on startup. try not to touch valves during job | |||||
| * | fix bug of reading ADC > channel 16 | Avi Levkovich | 2019-03-24 | 1 | -1/+1 | |
| | | ||||||
| * | Version 1.3.8.0 lock | Shlomo Hecht | 2019-03-19 | 1 | -2/+3 | |
| | | ||||||
| * | version 1.3.7.9 | Shlomo Hecht | 2019-03-14 | 1 | -0/+4 | |
| | | ||||||
| * | stop PID control when turning heaters off. improve heaters handling. thread ↵ | Shlomo Hecht | 2019-03-06 | 3 | -61/+96 | |
| | | | | | break test | |||||
| * | version 1.3.7.8 use flash for alarm and hw map. fix heaters problems. SWITCH ↵ | Shlomo Hecht | 2019-03-04 | 1 | -5/+50 | |
| | | | | | WASTE VALVE DIRECTION. prepare 100micro tests | |||||