| Commit message (Expand) | Author | Age | Files | Lines |
| ... | |
| * | HeaterBlowerMaxTempCBFunction | Ronen Sberlo | 2020-10-11 | 1 | -5/+12 |
| * | blower max temp | Ronen Sberlo | 2020-10-11 | 1 | -1/+1 |
| * | blower max temp controler tunnel pt100 fix | Ronen Sberlo | 2020-10-11 | 1 | -18/+5 |
| * | ifs filling / waste emptying interface | Shlomo Hecht | 2020-10-09 | 1 | -0/+1 |
| * | remove compilation warnings | Shlomo Hecht | 2020-10-08 | 1 | -1/+0 |
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Ronen Sberlo | 2020-10-07 | 1 | -1/+1 |
| |\ |
|
| | * | Head EEPROM stubs, pressurer sensor 2 read (WHS), | Shlomo Hecht | 2020-10-07 | 1 | -1/+1 |
| * | | set blower max temp to 255 | Ronen Sberlo | 2020-10-07 | 1 | -1/+1 |
| |/ |
|
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2020-10-06 | 1 | -12/+61 |
| |\ |
|
| | * | arc alarms, clean motor position on init | Ronen Sberlo | 2020-10-06 | 1 | -12/+61 |
| * | | valves mitigatio trial, heaters max temperature handling. IDS pressure buildi... | Shlomo Hecht | 2020-10-06 | 1 | -32/+72 |
| |/ |
|
| * | change cleaning motor to soft stop | Ronen Sberlo | 2020-09-30 | 1 | -0/+17 |
| * | bug fix in heaters | Shlomo Hecht | 2020-09-29 | 1 | -1/+1 |
| * | add stub to get blowers status | Ronen Sberlo | 2020-09-24 | 2 | -0/+7 |
| * | add stub to disable blowers PID | Ronen Sberlo | 2020-09-24 | 2 | -0/+16 |
| * | add comment | Ronen Sberlo | 2020-09-24 | 1 | -2/+2 |
| * | add compilation flag for tunnel pt100 | Ronen Sberlo | 2020-09-24 | 1 | -5/+31 |
| * | cleaning motor changes | Ronen Sberlo | 2020-09-21 | 1 | -2/+2 |
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2020-09-17 | 1 | -2/+2 |
| |\ |
|
| | * | change back to tunnel pt100 | Ronen Sberlo | 2020-09-15 | 1 | -2/+2 |
| * | | some bug fixes and changes | Shlomo Hecht | 2020-09-17 | 1 | -4/+5 |
| |/ |
|
| * | change polarity of arc actuator limit switch | Ronen Sberlo | 2020-09-14 | 1 | -10/+8 |
| * | change blower cp | Ronen Sberlo | 2020-09-08 | 1 | -1/+1 |
| * | add range check for head blower flow in process parameters | Ronen Sberlo | 2020-09-07 | 2 | -0/+21 |
| * | clean and improve diagnostics and machine status | Shlomo Hecht | 2020-09-06 | 1 | -2/+0 |
| * | bug fix - excluded mixer heaters together with the head heaters | Shlomo Hecht | 2020-09-06 | 1 | -6/+6 |
| * | some fixes in dispenser handling, implement setheaterstate, procedures and st... | Shlomo Hecht | 2020-09-06 | 2 | -0/+38 |
| * | blower bug fix | Ronen Sberlo | 2020-09-02 | 1 | -5/+8 |
| * | fix IDS presegment handling, Shinko PV display | Shlomo Hecht | 2020-08-31 | 1 | -2/+2 |
| * | arc head blowers PID | Ronen Sberlo | 2020-08-31 | 2 | -10/+144 |
| * | Tunnel entrances temperature read | Ronen Sberlo | 2020-08-30 | 1 | -2/+45 |
| * | arc head blowers and pressure sensor | Ronen Sberlo | 2020-08-27 | 2 | -1/+64 |
| * | some changes before 1.4.6.42/ mostly moving delay.c to utilities | Shlomo Hecht | 2020-08-16 | 1 | -1/+1 |
| * | Fix bug in the function HeadCard_Actuators_Stub | Avi Levkovich | 2020-07-30 | 1 | -10/+10 |
| * | initial blower value 2/3 of process value. build pressure in cleaner. stop jo... | Shlomo Hecht | 2020-07-27 | 1 | -1/+1 |
| * | some small changes, mostly in drier loading | Shlomo Hecht | 2020-07-23 | 1 | -3/+13 |
| * | Embedded SW Release note - Version 1.4.6.34 - Pack 2+ | Shlomo Hecht | 2020-06-29 | 1 | -9/+16 |
| * | heaters activation problem in I2C - surge of power. cancel overheat alarm whe... | Shlomo Hecht | 2020-06-25 | 1 | -11/+22 |
| * | update | Avi Levkovich | 2020-06-17 | 1 | -2/+2 |
| * | support dispensers jig station with DISPESER_TEST flag. | Shlomo Hecht | 2020-06-15 | 1 | -7/+20 |
| * | fixing some bugs in version 30 | Shlomo Hecht | 2020-06-09 | 1 | -2/+3 |
| * | stubs and logs, need cleaning | Shlomo Hecht | 2020-06-04 | 2 | -2/+22 |
| * | head eeprom failure causes bit failure and red activity led | Shlomo Hecht | 2020-06-01 | 1 | -2/+24 |
| * | heater changes to test heaters bugs | Shlomo Hecht | 2020-05-31 | 1 | -5/+17 |
| * | blower control info. turn off blower on INIT Vo calculation | Shlomo Hecht | 2020-05-20 | 1 | -1/+1 |
| * | fix current alarms (PP only). RFID stubs, | Shlomo Hecht | 2020-05-20 | 1 | -6/+6 |
| * | Version 1.4.6.26 #2: cartridge suction afetr extraction, waste tank reading i... | Shlomo Hecht | 2020-05-14 | 1 | -0/+1 |
| * | fix flash problems, whs problems | Shlomo Hecht | 2020-05-11 | 1 | -10/+21 |
| * | bug fixes and investigations. IFS brushstop closing, waste tank diagnostics, ... | Shlomo Hecht | 2020-05-10 | 1 | -9/+16 |
| * | fix whs control, remove some logs, cancel waste tank reading for now | Shlomo Hecht | 2020-05-07 | 1 | -2/+2 |