| Commit message (Collapse) | Author | Age | Files | Lines | ||
|---|---|---|---|---|---|---|
| ... | ||||||
| * | HeaterBlowerMaxTempCBFunction | Ronen Sberlo | 2020-10-11 | 1 | -5/+12 | |
| | | ||||||
| * | blower max temp | Ronen Sberlo | 2020-10-11 | 1 | -1/+1 | |
| | | ||||||
| * | blower max temp controler tunnel pt100 fix | Ronen Sberlo | 2020-10-11 | 1 | -18/+5 | |
| | | ||||||
| * | ifs filling / waste emptying interface | Shlomo Hecht | 2020-10-09 | 1 | -0/+1 | |
| | | ||||||
| * | remove compilation warnings | Shlomo Hecht | 2020-10-08 | 1 | -1/+0 | |
| | | ||||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Ronen Sberlo | 2020-10-07 | 1 | -1/+1 | |
| |\ | ||||||
| | * | Head EEPROM stubs, pressurer sensor 2 read (WHS), | Shlomo Hecht | 2020-10-07 | 1 | -1/+1 | |
| | | | ||||||
| * | | set blower max temp to 255 | Ronen Sberlo | 2020-10-07 | 1 | -1/+1 | |
| |/ | ||||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2020-10-06 | 1 | -12/+61 | |
| |\ | ||||||
| | * | arc alarms, clean motor position on init | Ronen Sberlo | 2020-10-06 | 1 | -12/+61 | |
| | | | ||||||
| * | | valves mitigatio trial, heaters max temperature handling. IDS pressure ↵ | Shlomo Hecht | 2020-10-06 | 1 | -32/+72 | |
| |/ | | | | building control.loading fixed. bug in winder prepare fixed, RFID tag update in Protobuf | |||||
| * | change cleaning motor to soft stop | Ronen Sberlo | 2020-09-30 | 1 | -0/+17 | |
| | | ||||||
| * | bug fix in heaters | Shlomo Hecht | 2020-09-29 | 1 | -1/+1 | |
| | | ||||||
| * | add stub to get blowers status | Ronen Sberlo | 2020-09-24 | 2 | -0/+7 | |
| | | ||||||
| * | add stub to disable blowers PID | Ronen Sberlo | 2020-09-24 | 2 | -0/+16 | |
| | | ||||||
| * | add comment | Ronen Sberlo | 2020-09-24 | 1 | -2/+2 | |
| | | ||||||
| * | add compilation flag for tunnel pt100 | Ronen Sberlo | 2020-09-24 | 1 | -5/+31 | |
| | | ||||||
| * | cleaning motor changes | Ronen Sberlo | 2020-09-21 | 1 | -2/+2 | |
| | | ||||||
| * | Merge branch 'master' of https://twinetfs.visualstudio.com/Tango/_git/Tango | Shlomo Hecht | 2020-09-17 | 1 | -2/+2 | |
| |\ | ||||||
| | * | change back to tunnel pt100 | Ronen Sberlo | 2020-09-15 | 1 | -2/+2 | |
| | | | ||||||
| * | | some bug fixes and changes | Shlomo Hecht | 2020-09-17 | 1 | -4/+5 | |
| |/ | ||||||
| * | change polarity of arc actuator limit switch | Ronen Sberlo | 2020-09-14 | 1 | -10/+8 | |
| | | ||||||
| * | change blower cp | Ronen Sberlo | 2020-09-08 | 1 | -1/+1 | |
| | | ||||||
| * | add range check for head blower flow in process parameters | Ronen Sberlo | 2020-09-07 | 2 | -0/+21 | |
| | | ||||||
| * | clean and improve diagnostics and machine status | Shlomo Hecht | 2020-09-06 | 1 | -2/+0 | |
| | | ||||||
| * | bug fix - excluded mixer heaters together with the head heaters | Shlomo Hecht | 2020-09-06 | 1 | -6/+6 | |
| | | ||||||
| * | some fixes in dispenser handling, implement setheaterstate, procedures and ↵ | Shlomo Hecht | 2020-09-06 | 2 | -0/+38 | |
| | | | | | stubs updated | |||||
| * | blower bug fix | Ronen Sberlo | 2020-09-02 | 1 | -5/+8 | |
| | | ||||||
| * | fix IDS presegment handling, Shinko PV display | Shlomo Hecht | 2020-08-31 | 1 | -2/+2 | |
| | | ||||||
| * | arc head blowers PID | Ronen Sberlo | 2020-08-31 | 2 | -10/+144 | |
| | | ||||||
| * | Tunnel entrances temperature read | Ronen Sberlo | 2020-08-30 | 1 | -2/+45 | |
| | | ||||||
| * | arc head blowers and pressure sensor | Ronen Sberlo | 2020-08-27 | 2 | -1/+64 | |
| | | ||||||
| * | some changes before 1.4.6.42/ mostly moving delay.c to utilities | Shlomo Hecht | 2020-08-16 | 1 | -1/+1 | |
| | | ||||||
| * | Fix bug in the function HeadCard_Actuators_Stub | Avi Levkovich | 2020-07-30 | 1 | -10/+10 | |
| | | ||||||
| * | initial blower value 2/3 of process value. build pressure in cleaner. stop ↵ | Shlomo Hecht | 2020-07-27 | 1 | -1/+1 | |
| | | | | | job on waste overlow or cartridge inserted | |||||
| * | some small changes, mostly in drier loading | Shlomo Hecht | 2020-07-23 | 1 | -3/+13 | |
| | | ||||||
| * | Embedded SW Release note - Version 1.4.6.34 - Pack 2+ | Shlomo Hecht | 2020-06-29 | 1 | -9/+16 | |
| | | | | | | | | | | | | | | | | ============================================================= Validate IFS and cartridge location on manual waste handling - bug #3033 better handling of powerstep01 configuration and motors clocks waste level: logs, fixed reading during waste filling, fix PT100 reading in WHS //important, OK improve diespensers reading in I2C timing //important OK alarm handling: fix report (mid tank empty) diagnostics - waste level in liters Heating and process - avoid activating all heaters at once. tested for flat head. Heating - remove alarms when colling dwn due to change of RML or idle mode Thread - improve feeder tension handling system: hold initalization process after 3 failures to enable code / parameters change and debugging | |||||
| * | heaters activation problem in I2C - surge of power. cancel overheat alarm ↵ | Shlomo Hecht | 2020-06-25 | 1 | -11/+22 | |
| | | | | | when changing RML, improve thread feeder tension, set tension parameter on stub, | |||||
| * | update | Avi Levkovich | 2020-06-17 | 1 | -2/+2 | |
| | | ||||||
| * | support dispensers jig station with DISPESER_TEST flag. | Shlomo Hecht | 2020-06-15 | 1 | -7/+20 | |
| | | | | | try to fix hardware init bug - not during job, fix watchdog (#3016). internal alrm stops job. accurate brushstops, winder cone alarm and job failures | |||||
| * | fixing some bugs in version 30 | Shlomo Hecht | 2020-06-09 | 1 | -2/+3 | |
| | | ||||||
| * | stubs and logs, need cleaning | Shlomo Hecht | 2020-06-04 | 2 | -2/+22 | |
| | | ||||||
| * | head eeprom failure causes bit failure and red activity led | Shlomo Hecht | 2020-06-01 | 1 | -2/+24 | |
| | | | | | | | whs eeprom failure causes bit failure and orange activity led secondary heater deactivated when not active file system control failures | |||||
| * | heater changes to test heaters bugs | Shlomo Hecht | 2020-05-31 | 1 | -5/+17 | |
| | | ||||||
| * | blower control info. turn off blower on INIT Vo calculation | Shlomo Hecht | 2020-05-20 | 1 | -1/+1 | |
| | | ||||||
| * | fix current alarms (PP only). RFID stubs, | Shlomo Hecht | 2020-05-20 | 1 | -6/+6 | |
| | | ||||||
| * | Version 1.4.6.26 #2: cartridge suction afetr extraction, waste tank reading ↵ | Shlomo Hecht | 2020-05-14 | 1 | -0/+1 | |
| | | | | | improved | |||||
| * | fix flash problems, whs problems | Shlomo Hecht | 2020-05-11 | 1 | -10/+21 | |
| | | ||||||
| * | bug fixes and investigations. IFS brushstop closing, waste tank diagnostics, ↵ | Shlomo Hecht | 2020-05-10 | 1 | -9/+16 | |
| | | | | | heaters hangout handling | |||||
| * | fix whs control, remove some logs, cancel waste tank reading for now | Shlomo Hecht | 2020-05-07 | 1 | -2/+2 | |
| | | ||||||