aboutsummaryrefslogtreecommitdiffstats
path: root/Software/Embedded_SW/Embedded/Modules/IDS/IDS_dispenser.c
Commit message (Collapse)AuthorAgeFilesLines
* fix bug in pre-run PBU, and in dispensers 25%. 50% indicationsShlomo Hecht2021-01-061-2/+2
|
* PBU in pre-run preparationsShlomo Hecht2021-01-051-5/+2
|
* some logs on dispensers' 50% and 25% pointsShlomo Hecht2020-12-231-0/+37
|
* Version 1.6.0 mostly changes in flash and EEPROMShlomo Hecht2020-12-201-6/+15
|
* some fixes in dispenser handling, implement setheaterstate, procedures and ↵Shlomo Hecht2020-09-061-2/+6
| | | | stubs updated
* remove a debug codeShlomo Hecht2020-09-061-3/+3
|
* extended tracing in dispenser 3 consumption. improvements in thread loadingShlomo Hecht2020-09-061-2/+5
|
* replace report with filter reportShlomo Hecht2020-08-301-31/+31
|
* prevent turning off the blower (#3166). fix ink calculation (resolves #3174, ↵Shlomo Hecht2020-07-151-2/+3
| | | | #2956, #3140, #2375) feeder start jumps (resolves #3163, #3104)
* Version 1.4.6.26 #2: cartridge suction afetr extraction, waste tank reading ↵Shlomo Hecht2020-05-141-1/+1
| | | | improved
* fix flash problems, whs problemsShlomo Hecht2020-05-111-1/+1
|
* Version 1.4.6.20 - Head Cleaning from PPC, Dye sequence stubs (special ↵Shlomo Hecht2020-03-311-4/+5
| | | | dispensers, WCF, Waste time)
* Version 1.4.6.19 new RML parameters, tension spring handling, some bug fixingShlomo Hecht2020-03-251-2/+2
|
* preparing rapid releaseShlomo Hecht2020-02-181-3/+3
|
* Version 1.4.6.7 : beginning of removing the #ifdefs. Sylco head and arc head ↵Shlomo Hecht2020-01-301-1/+0
| | | | temperature control fixed. new events (version 18),
* updating : special dispensers handling (for Moti), new process parameters, ↵Shlomo Hecht2020-01-261-9/+25
| | | | bugs and features. merged with Shai
* device information and time stamps on diagnosticsShlomo Hecht2020-01-191-13/+18
|
* Version 1.4.6.4: fix diagnostics, alarm handling data loading, fix heaters - ↵Shlomo Hecht2020-01-141-1/+1
| | | | new head is working. new TPF files for new head
* some fixes from 1.4.5.110 (Beta +)Shlomo Hecht2020-01-061-2/+2
|
* update mastrer with latest changes in Alpha + embedded versionShlomo Hecht2019-11-191-5/+5
|
* version 1.4.6.0 - going forwardShlomo Hecht2019-10-311-3/+9
|
* remove file writing in dispenser dataShlomo Hecht2019-10-161-4/+4
|
* Version 1.4.4.9 handle safety alarms better. winder logging. inactive ↵Shlomo Hecht2019-09-221-1/+1
| | | | dispenser homing
* handle safety alarms, log winder better.Shlomo Hecht2019-09-221-6/+7
|
* handling midtank calibration messageShlomo Hecht2019-09-041-0/+1
|
* fix microstep and prepare for motor type changeShlomo Hecht2019-08-191-19/+1
|
* Version 1.4.3.7 VOC sensors, disable saving dispenser data to flash during a ↵Shlomo Hecht2019-08-141-10/+14
| | | | job (winder jump), screw encoder data,power off and init improved.
* Version 1.4.3.5: prepare for dispenser filling. VOC alarms. fix alarm ↵Shlomo Hecht2019-08-121-1/+1
| | | | handling. improved IDS and other features
* Version 1.4.3.0 Embedded SW Release note - Version 1.4.3.0Shlomo Hecht2019-08-011-8/+2
| | | | | | | | | | | | | | | | | | | | ============================================================= System: File system protection + improvements Keep critical data on MCU EEPROM Procedures: Thread load fix and coordinate the amount of thread in drier to the distance to spool length. Dispensers flow control stage 2a - maintain pressure during presegment Modules: Enclosure temperature alarms Secondary waste pump Dispensers state info Heaters protection improved Diagnostics data - full data, full speed for now Thread - fix length calculation Process: Cleaning ready for integration
* Version 1.4.2.8 improved loading, cleaning introduced, time handledShlomo Hecht2019-07-301-2/+5
|
* improve loading, dispensers handling. stubsShlomo Hecht2019-07-281-2/+2
|
* for version 1.4.2.7 : syc file system with semaphore (needs testing!). add ↵Shlomo Hecht2019-07-281-1/+1
| | | | secondary pump and activation on init and after 8 hours.now config parameters, improved thread load
* Version 1.4.2.5 store data in EEPROM, thread loading, IDS datat store, IDS ↵Shlomo Hecht2019-07-231-3/+14
| | | | prepare with reduced ink usage
* cosmeticsShlomo Hecht2019-07-161-1/+1
|
* bug fixShlomo Hecht2019-07-151-1/+0
|
* Version 1.4.2.2 report filters introduced, improved flash handling. ↵Shlomo Hecht2019-07-151-39/+93
| | | | improved and simplified dispenser location. improved config parameters handling
* Version 1.3.9.32 reduced diagnostics. new ITMA screens. heating improved. ↵Shlomo Hecht2019-04-301-1/+10
| | | | lubricant handled better
* Version 1.3.8.49 dispenser data request, added config params (support ↵Shlomo Hecht2019-04-141-0/+20
| | | | pending). improvements in heating control, automatic refill at the end of job
* fix first dispenser not moving bugShlomo Hecht2019-04-101-2/+3
|
* version 1.3.8.3 Power down scenario, Idle handling, some thread load ↵Shlomo Hecht2019-04-031-14/+20
| | | | improvements
* fix brushstop stop dispensers bugShlomo Hecht2019-04-021-4/+4
|
* Embedded SW Release note - Version 1.3.8.2Shlomo Hecht2019-04-021-1/+1
| | | | | | | | | File upload: prevent on job, reduce priority (watchdog) Report: packages filters introduced, please feel free to use them. robustness in communication improved large number of segments and gradient support - initial at the end of job the screw does not return back rockers - adjust values before and after loading the cart
* Version 1.3.8.12 printing function calls with segments info. ids - no ↵Shlomo Hecht2019-03-271-3/+4
| | | | valves. improved winding. dispensers pressure build on startup. try not to touch valves during job
* PreVersion 1.3.8.1 lubrication, IDS presegment improvement start. alarm ↵Shlomo Hecht2019-03-191-2/+8
| | | | handling improved, pressure buildup on init, improve centering of drier arm. NON Operative, NOT TESTED!
* Version 1.3.8.0 lockShlomo Hecht2019-03-191-8/+2
|
* version 1.3.7.9Shlomo Hecht2019-03-141-2/+8
|
* version 1.3.7.88: send parameters on job request. no initial heating. ↵Shlomo Hecht2019-03-111-12/+12
| | | | removed some logs
* dispenser info logsShlomo Hecht2019-03-101-0/+3
|
* suspend FAN checking pending tests. initial fix for dispensers storageShlomo Hecht2019-03-101-1/+12
|
* do not touch valve on segment start if the motor is already runningShlomo Hecht2019-03-051-10/+23
|