aboutsummaryrefslogtreecommitdiffstats
path: root/Software/Visual_Studio/Tango.Video
Commit message (Collapse)AuthorAgeFilesLines
* Machine Studio v3.5.57Roy Ben-Shabat2018-11-011-1/+1
|
* New color conversion.Roy Ben-Shabat2018-11-011-1/+1
| | | | | | Added new pid parameters. Changes dispenser widget orientation. Modified NoneEmptyIdsPacks to GetSupportedIdsPacks.
* Sign-out works !Roy Ben-Shabat2018-10-101-1/+1
| | | | | Fixed issue where color conversion was busy while not in research module but research module in job view. Added new RealTimeGraphX !
* BACK TO .NET 4.6 !!Roy Ben-Shabat2018-10-071-1/+1
|
* Added new colorized static text widget to tech board.Roy Ben-Shabat2018-08-261-1/+1
| | | | | | Added option to go back to job/jobs from running job view. Fixed issue with bug reporting. Fixed other bugs.
* Fixed some issues with MS 3.0Roy Ben-Shabat2018-08-231-1/+1
|
* Refactored ObservablesContext to use DataSource object!Roy Ben-Shabat2018-08-211-1/+1
| | | | Upgraded to .NET 4.7.2 !!!
* Machine Studio v2.8Roy Ben-Shabat2018-08-141-1/+1
|
* Reorganization of solution build paths !Roy Ben-Shabat2018-08-141-3/+3
| | | | Optimized production packages.
* Machine Studio v2.7Roy Ben-Shabat2018-08-071-1/+1
|
* 1. Top priority: When stopping job (stop button), the system cannot run ↵Roy Ben-Shabat2018-08-071-1/+1
| | | | | | | | | | | | | | | | | again (notes it is still printing). Disconnectconnect solves 2. Dispenser manual control (tech bord) a. Add Color and name to the dispenser controller at the tech-bord b. Homing dosnt work on the tech-bord controller c. When moving the courser from the icon while still pushing and then removing the finger, the motor still running d. Limit sw are not activated in manual dispenser jogging 3. Read dispenser pressure manually separately for each dispenser 4. High priority: Dispenser pressure is presented in PSI (that’s what written..) ?? I am not sure that the formula is correct even for PSI.. 5. TI is calculated in the job by factor and not by min uptake (factor for TI is meaningless) 6. Top priority: TI dispensing amounts are constant: Changing TI amounts by factor did not change the total amount of dispensing (tested by flow sensor) 7. I would like to monitor (tech bord) the RPM or pulse rate of all possible motors (priority: thread system, dispensers, others) 8. I would like to monitor (tech bord) the status of the 3Wvalves of the dispensers (open / close) 9. Top priority: Cannot read head temperatures
* Machine Studio v2.4Roy Ben-Shabat2018-08-061-1/+1
|
* Working on SQLExaminer libRoy Ben-Shabat2018-08-021-1/+1
|
* Machine Studio v2.0.9Roy Ben-Shabat2018-07-251-1/+1
|
* Implemented revision number as delta years and day of year for auto ↵Roy Ben-Shabat2018-07-231-1/+1
| | | | incremented versions.
* Redundant.Roy Ben-Shabat2018-07-231-1/+1
|
* New version numbers using Auto Increment Versions visual studio extension !Roy Ben-Shabat2018-07-232-2/+2
|
* Changed versions to per assembly.Roy Ben-Shabat2018-07-232-2/+8
|
* Split assembly versions to Core, Machine Studio, PPC!Roy Ben-Shabat2018-06-201-2/+2
|
* Implemented video recording on Data Capture Module!Roy Ben-Shabat2018-03-221-0/+23
|
* Working on machine studio update center..Roy Ben-Shabat2018-02-211-3/+5
|
* Added Tango.Video project.Roy Ben-Shabat2018-02-0133-0/+3240
Implemented USB video device capture for developer module.