From c14073e78d2c5b9569f91f47609d431da48ba706 Mon Sep 17 00:00:00 2001 From: Roy Ben-Shabat Date: Sun, 6 May 2018 13:50:14 +0300 Subject: Added start/stop diagnostics and debugging on PMR. Added device info to connected machine view. Added enable/disable diagnostics/debugging to connected machine view. Improved transfer rate calculation. --- .../Modules/Tango.MachineStudio.DataCapture/ViewModels/MainViewVM.cs | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.DataCapture') diff --git a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.DataCapture/ViewModels/MainViewVM.cs b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.DataCapture/ViewModels/MainViewVM.cs index 40a407093..fdd0fed5b 100644 --- a/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.DataCapture/ViewModels/MainViewVM.cs +++ b/Software/Visual_Studio/MachineStudio/Modules/Tango.MachineStudio.DataCapture/ViewModels/MainViewVM.cs @@ -239,7 +239,7 @@ namespace Tango.MachineStudio.DataCapture.ViewModels InvalidateRelayCommands(); } - private void _frameProvider_FrameReceived(object sender, PushDiagnosticsResponse frame) + private void _frameProvider_FrameReceived(object sender, StartDiagnosticsResponse frame) { if (!_frameProvider.Disable) { @@ -358,7 +358,7 @@ namespace Tango.MachineStudio.DataCapture.ViewModels { if (_frameProvider.Disable) { - _frameProvider.PushFrame(frame.PushDiagnosticsResponse); + _frameProvider.PushFrame(frame.StartDiagnosticsResponse); CaptureDevices.First().BeginInvoke(() => { -- cgit v1.3.1