1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
|
using System;
using System.Text;
using System.IO;
using System.Linq;
using System.Drawing;
using System.Diagnostics;
using System.Windows.Forms;
using System.Threading;
using System.Threading.Tasks;
using System.Collections.Generic;
using Tango.PMR.Stubs;
using Tango.Stubs;
using System.Timers;
const int MidTank_UNDER_TEST =24;
int [] Convert_Midtank_No = new Int32 [8] {1,3,5,7,2,4,6,8};
uint [,] ADC_Add_Chnl = new uint [8,2] {
{0x44,0x20},
{0x44,0x08},
{0x46,0x80},
{0x46,0x20},
{0x44,0x10},
{0x44,0x04},
{0x46,0x40},
{0x46,0x10},
};
string [,] Units_status_MidTank = new string[MidTank_UNDER_TEST,2] {
{"Midtank1_Valve_Air","Not Test"}, //0
{"Midtank1_Valve_Ink","Not Test"}, //1
{"Midtank1_Pressure_Sensor","Not Test"}, //2
{"Midtank2_Valve_Air","Not Test"}, //3
{"Midtank2_Valve_Ink","Not Test"}, //4
{"Midtank2_Pressure_Sensor","Not Test"}, //5
{"Midtank3_Valve_Air","Not Test"}, //6
{"Midtank3_Valve_Ink","Not Test"}, //7
{"Midtank3_Pressure_Sensor","Not Test"}, //8
{"Midtank4_Valve_Air","Not Test"}, //9
{"Midtank4_Valve_Ink","Not Test"}, //10
{"Midtank4_Pressure_Sensor","Not Test"}, //11
{"Midtank5_Valve_Air","Not Test"}, //12
{"Midtank5_Valve_Ink","Not Test"}, //13
{"Midtank5_Pressure_Sensor","Not Test"}, //14
{"Midtank6_Valve_Air","Not Test"}, //15
{"Midtank6_Valve_Ink","Not Test"}, //16
{"Midtank6_Pressure_Sensor","Not Test"}, //17
{"Midtank7_Valve_Air","Not Test"}, //18
{"Midtank7_Valve_Ink","Not Test"}, //19
{"Midtank7_Pressure_Sensor","Not Test"}, //20
{"Midtank8_Valve_Air","Not Test"}, //21
{"Midtank8_Valve_Ink","Not Test"}, //22
{"Midtank8_Pressure_Sensor","Not Test"}, //23
};
//--------------------------------------------------------------------------------
public Task<decimal> MidTank_test( Action<string> settext, CancellationToken cancellationToken, string SN, string Location)
{
Task<decimal> task = null;
// Start a task and return it
task = Task.Run(() =>
{
stubManager.Write("S/N:" +SN+ "\n");
stubManager.Write("Location:" +Location+ "\n");
stubManager.Write("-----------------------\n");
copy_table (MidTank_UNDER_TEST,Units_status_MidTank);
stubManager.Write("+++++++++++++++++++\n");
settext("Test MidTank");
Test_MIDTANK();
Status=write_to_file(SN,Location,MidTank_UNDER_TEST,"MidTank");
settext("End Test");
decimal result = 0;
return result;
});
return task;
}
//------------------------------------
int Test_MIDTANK()
{
double Pressur_Volt;
double temp;
for (Int32 i=1;i<9;i++)
{
open_valve(i,1,1) ; //open Air valve
open_valve(i,0,1) ; //open Ink valve
delay(2000);
Pressur_Volt=read_pressuere_sense(i);
if ((Pressur_Volt>3 )||(Pressur_Volt<2))
{
Units_status[(i-1)*3+2,1]="Fail";
stubManager.Write("pressuere_sense of midtank" + i +"\tFail\n");
}
else
{
close_valve(i,0,0) ; //close Ink valve
DialogResult result = MessageBox.Show("ADD 20cc air thru Ink valve of Midtank"+ i, "Warning");
close_valve(i,1,0) ; //close Air valve
delay(2000);
temp=read_pressuere_sense(i);
temp=temp-Pressur_Volt;
if ((temp>0.5) && ( temp <2))
Units_status[(i-1)*3+2,1]="Pass";
else
Units_status[(i-1)*3+2,1]="Fail";
}
close_valve(i,0,0) ; //close Air valve
close_valve(i,1,0) ; //close Ink valve
}
return 1;
}
double read_pressuere_sense(Int32 Midtank_Nm)
{
double Pressur_Volt;
double calc;
uint temp;
adc_configuration((ADC_Add_Chnl[Midtank_Nm-1,0]),(ADC_Add_Chnl[Midtank_Nm-1,1]) ); //configure address and channel of midtank
adc_set_for_read_ch(ADC_Add_Chnl[Midtank_Nm-1,0]);
temp =adc_read_ch(ADC_Add_Chnl[Midtank_Nm-1,0]);
calc= (double)temp *2.5 / 4096.0;
Pressur_Volt = (1.96- calc) * 4.64 + 1.96;
stubManager.Write("pressure sense of midtank " + Midtank_Nm + "is " + Pressur_Volt+ "Volt\n");
return Pressur_Volt;
}
//--------------------------------
int open_valve (int valve_nm,int valve_type,int check_valve) //valve_type=0 is Air ,1 is Ink ; check_valve=1 send feedbak
{
int temp1=Convert_Midtank_No[valve_nm-1] ;
string temp;
SetBit (F3_VALVE_OUT,(((valve_type+1)*8)- temp1), 1);
if (check_valve!=0)
{
temp="Air ";
if (valve_type==1)
temp="Ink ";
DialogResult result = MessageBox.Show("Did " + temp + "Valve of Midtank " + valve_nm +" open?", "Warning",MessageBoxButtons.YesNo);
if(result == DialogResult.No)
{
Units_status[(valve_nm-1)*3+valve_type,1]="Fail";
stubManager.Write(temp +"Valve\tFail\n");
return 0;
}
else
{
Units_status[(valve_nm-1)*3+valve_type,1]="Pass";
stubManager.Write(temp +"Valve\tOpen\n");
return 1;
}
}
return 1;
}
//--------------------------------
int close_valve (int valve_nm,int valve_type,int check_valve)
{
int temp1=Convert_Midtank_No[valve_nm-1];
string temp;
SetBit (F3_VALVE_OUT,(((valve_type+1)*8)- temp1), 0);
if (check_valve!=0)
{
temp="Air";
if (valve_type==1)
temp="Ink";
DialogResult result = MessageBox.Show("Did " + temp +" Valve of Midtank " + valve_nm +" close?", "Warning",MessageBoxButtons.YesNo);
if(result == DialogResult.No)
{
Units_status[(valve_nm-1)*3+valve_type,1]="Fail";
stubManager.Write(temp +"Valve\tFail\n");
return 0;
}
else
{
Units_status[(valve_nm-1)*3+valve_type,1]="Pass";
stubManager.Write(temp +"Valve\tclose\n");
return 1;
}
}
return 1;
}
//--------------------------------
|