1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
|
using System;
using System.Collections.Generic;
using System.Collections.ObjectModel;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using Tango.DispenserAnalyzer.UI.Models;
using Tango.SharedUI;
namespace Tango.DispenserAnalyzer.UI.ViewModels
{
public class SettingsVM : ViewModel, IDisposable
{
private ObservableCollection<SettingsModel> _PBUSettings;
public ObservableCollection<SettingsModel> PBUTestSettings
{
get { return _PBUSettings; }
set { _PBUSettings = value; RaisePropertyChangedAuto(); }
}
private ObservableCollection<SettingsModel> _flowTestSettings;
public ObservableCollection<SettingsModel> FlowTestSettings
{
get { return _flowTestSettings; }
set { _flowTestSettings = value; RaisePropertyChangedAuto(); }
}
private Dictionary<AnalyzerSettingsEnum, double> changedValues;
public SettingsVM()
{
_PBUSettings = new ObservableCollection<SettingsModel>();
InitPBUTestSettings();
_flowTestSettings = new ObservableCollection<SettingsModel>();
changedValues = new Dictionary<AnalyzerSettingsEnum, double>();
InitFlowTestSettings();
}
private void InitPBUTestSettings()
{
var setting = new SettingsModel(AnalyzerSettingsEnum.PBUPassFail, "4.5 sec");
setting.SettingValueEvent += new EventHandler(OnSettingValueChanged);
_PBUSettings.Add(setting);
}
private void InitFlowTestSettings()
{
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.FlowPBUPassFail, "4.5 sec"));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.ExcludeAnalysis, "1800 reads"));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.AvgMinValue, "1400-1850 [mbar]", true));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxMinRange, "500 reads"));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxMinIntervals, "300 reads"));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxError, "1.5%"));
_flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.TakeOffMaxMin, "3"));
_flowTestSettings.ToList().ForEach(x => x.SettingValueEvent += new EventHandler(OnSettingValueChanged));
}
private void OnSettingValueChanged(object sender, EventArgs e)
{
if(sender is SettingsModel)
{
SettingsModel settingModel = sender as SettingsModel;
if(settingModel.IsRangeVisible)
{
changedValues[AnalyzerSettingsEnum.AvgMinValue] = settingModel.MinRangeValue;
changedValues[AnalyzerSettingsEnum.AvgMaxValue] = settingModel.MaxRangeValue;
}
else
changedValues[settingModel._enumName] = settingModel.PropertyValue;
}
}
public Dictionary<AnalyzerSettingsEnum, double> GetChanges()
{
return changedValues;
}
public void Dispose()
{
_PBUSettings.ToList().ForEach(x => x.SettingValueEvent -= OnSettingValueChanged);
_flowTestSettings.ToList().ForEach(x => x.SettingValueEvent -= OnSettingValueChanged);
}
}
}
|