using System;
using System.Collections.Generic;
using System.Collections.ObjectModel;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using Tango.DispenserAnalyzer.UI.Models;
using Tango.SharedUI;

namespace Tango.DispenserAnalyzer.UI.ViewModels
{
    public class SettingsVM : ViewModel, IDisposable
    {
        private ObservableCollection<SettingsModel> _PBUSettings;

        public ObservableCollection<SettingsModel> PBUTestSettings
        {
            get { return _PBUSettings; }
            set { _PBUSettings = value; RaisePropertyChangedAuto(); }
        }

        private ObservableCollection<SettingsModel> _flowTestSettings;

        public ObservableCollection<SettingsModel> FlowTestSettings
        {
            get { return _flowTestSettings; }
            set { _flowTestSettings = value; RaisePropertyChangedAuto(); }
        }

        private Dictionary<AnalyzerSettingsEnum, double> changedValues;

        public SettingsVM()
        {
            _PBUSettings = new ObservableCollection<SettingsModel>();
            InitPBUTestSettings();
            _flowTestSettings = new ObservableCollection<SettingsModel>();
            changedValues = new Dictionary<AnalyzerSettingsEnum, double>();
            InitFlowTestSettings();
        }

        private void InitPBUTestSettings()
        {
            var setting = new SettingsModel(AnalyzerSettingsEnum.PBUPassFail, "4.5 sec");
            setting.SettingValueEvent += new EventHandler(OnSettingValueChanged);
            _PBUSettings.Add(setting);
        }

        private void InitFlowTestSettings()
        {
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.FlowPBUPassFail, "4.5 sec"));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.ExcludeAnalysis, "1800 reads"));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.AvgMinValue, "1400-1850 [mbar]", true));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxMinRange, "500 reads"));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxMinIntervals, "300 reads"));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.MaxError, "1.5%"));
            _flowTestSettings.Add(new SettingsModel(AnalyzerSettingsEnum.TakeOffMaxMin, "3"));
            
            _flowTestSettings.ToList().ForEach(x => x.SettingValueEvent += new EventHandler(OnSettingValueChanged));
        }

        private void OnSettingValueChanged(object sender, EventArgs e)
        {
            if(sender is SettingsModel)
            {
                SettingsModel settingModel = sender as SettingsModel;
                if(settingModel.IsRangeVisible)
                {
                    changedValues[AnalyzerSettingsEnum.AvgMinValue] = settingModel.MinRangeValue;
                    changedValues[AnalyzerSettingsEnum.AvgMaxValue] = settingModel.MaxRangeValue;
                }
                else
                  changedValues[settingModel._enumName] = settingModel.PropertyValue;
            }
        }

        public Dictionary<AnalyzerSettingsEnum, double> GetChanges()
        {
            return changedValues;
        }

        public void Dispose()
        {
            _PBUSettings.ToList().ForEach(x => x.SettingValueEvent -= OnSettingValueChanged);
            _flowTestSettings.ToList().ForEach(x => x.SettingValueEvent -= OnSettingValueChanged);
        }
    }
}